Typical values of pediatric interventional cardiology procedures in Beijing, China: a multicenter cross-sectional study
Radiation Protection Dosimetry · 02.01.2026 · 202 (1) · 15-21
DOI: 10.1093/rpd/ncaf149 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 08.12.2025. Verfasst von Jun Yu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Protection, Beijing Center for Disease Prevention and Control, No. 16, Hepingli Middle Street, Dongcheng District, 100013, Be…. Hauptthemen laut MEDLINE: Radiography, Interventional, Cardiology. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Gefördert von: Capital's Funds for Health Improvement and Research, CFH, Capital’s Funds for Health Improvement and Research, CFH.
Abstract (Originalsprache)
Children receive high radiation doses during interventional cardiology procedures and their sensitivity to radiation is higher than that of adults. A 4-year follow-up study was conducted in two large cardiovascular hospitals and a pediatric polyclinic with the objective of providing typical values. The median values of 454 cases obtained for fluoroscopy time, cumulative reference point air kerma (Ka,r) and air kerma-area product (PKA) by age range were 5.6 min, 53.6 mGy, and 4.1 Gy cm2 for <1 y; 4.3 min, 77.9 mGy, and 7.2 Gy cm2 for 1 to <5 y; 4.0 min, 41.4 mGy, and 7.4 Gy cm2 for 5 to <10 y; 4.4 min, 90.1 mGy, and 16.1 Gy cm2 for 10 to <16 y, respectively. The median values of 144 cases obtained for Ka,r and PKA by weight bands were 84.4 mGy and 7.4 Gy cm2 for <15 kg, 25.8 mGy and 3.7 Gy cm2 for 15–30 kg, 46.4 mGy and 9.2 Gy cm2 for 30–50 kg, and 154.0 mGy and 25.6 Gy·cm2 for >50 kg. Our results can serve as a dose comparison with local practice and as a basis for optimization between facilities.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiation Protection, Beijing Center for Disease Prevention and Control, No. 16, Hepingli Middle Street, Dongcheng District, 100013, Beijing, China.
ORCID-Profile: Limeng Cui
Förderung
- Capital's Funds for Health Improvement and Research, CFH
- Capital’s Funds for Health Improvement and Research, CFH
Zitieren
APA
Yu, J., Cui, L., Feng, Z., & Ma, Y. (2026). Typical values of pediatric interventional cardiology procedures in Beijing, China: a multicenter cross-sectional study. Radiation Protection Dosimetry, 202(1), 15-21. https://doi.org/10.1093/rpd/ncaf149
Vancouver
Yu J, Cui L, Feng Z, Ma Y. Typical values of pediatric interventional cardiology procedures in Beijing, China: a multicenter cross-sectional study. Radiation Protection Dosimetry. 2026;202(1):15-21. doi:10.1093/rpd/ncaf149
BibTeX
@article{Yu2026,
author = {Yu, Jun and Cui, Limeng and Feng, Zechen and Ma, Yongzhong},
title = {Typical values of pediatric interventional cardiology procedures in Beijing, China: a multicenter cross-sectional study},
journal = {Radiation Protection Dosimetry},
year = {2026},
volume = {202},
number = {1},
pages = {15--21},
doi = {10.1093/rpd/ncaf149}
}
EUVIMED