Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy
Radiation Protection Dosimetry · 2025
DOI: 10.1093/rpd/ncaf103 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Masaki Onoe und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Shimane University School of Medicine, Izumo, Shimane, Japan. Hauptthemen laut MEDLINE: Occupational Exposure, Endoscopy, Radiation Protection, Health Personnel. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background and aims: Healthcare professionals involved in fluoroscopy-guided endoscopy are occupationally exposed to ionizing radiation. We evaluated whether a patient-immobilization device, MEDO V-Fix®, reduces this exposure.
Methods
Monthly effective and lens equivalent dose were measured for nurses and doctors using personal dosemeters worn inside protective gear. Data from 7 months before and 10 months after device introduction were compared. Additionally a cost–benefit analysis (CBA) of dose reduction was performed.
Results
Monthly effective doses fell in both professions, but neither decline reached statistical significance. By contrast, nurses’ mean lens-equivalent dose dropped sharply from 35.0 to 6.5 μSv per procedure (P < 0.01), whereas the reduction in doctors was not significant. In the CBA, assuming a 5-y service life, the benefit-to-cost ratio ranged 1.02–2.72, indicating economic merit.
Conclusions
The MEDO V-Fix significantly reduces the occupational radiation exposure of endoscopy nurses and is a worthwhile investment from a CBA perspective.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Gastroenterology and Hepatology, Shimane University School of Medicine, Izumo, Shimane, Japan.
- Department of Endoscopy, Shimane University Hospital, Izumo, Shimane, Japan.
ORCID-Profile: Masaki Onoe, Nobuhiko Fukuba, Yasuhide Kodama, Satoshi Kotani, Akihiko Oka, Naoki Oshima, Kousaku Kawashima, Norihisa Ishimura, Shunji Ishihara
Zitieren
APA
Onoe, M., Fukuba, N., Kodama, Y., Kotani, S., Oka, A., Oshima, N., Shibagaki, K., Kawashima, K., Ishimura, N., & Ishihara, S. (2025). Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf103
Vancouver
Onoe M, Fukuba N, Kodama Y, Kotani S, Oka A, Oshima N, et al. Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf103
BibTeX
@article{Onoe2025,
author = {Onoe, Masaki and Fukuba, Nobuhiko and Kodama, Yasuhide and Kotani, Satoshi and Oka, Akihiko and Oshima, Naoki and Shibagaki, Kotaro and Kawashima, Kousaku and Ishimura, Norihisa and Ishihara, Shunji},
title = {Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy},
journal = {Radiation Protection Dosimetry},
year = {2025},
doi = {10.1093/rpd/ncaf103}
}
EUVIMED