Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy

Masaki Onoe iD, Nobuhiko Fukuba iD, Yasuhide Kodama iD, Satoshi Kotani iD, Akihiko Oka iD, Naoki Oshima iD, Kotaro Shibagaki, Kousaku Kawashima iD, Norihisa Ishimura iD, Shunji Ishihara iD

Radiation Protection Dosimetry · 2025

DOI: 10.1093/rpd/ncaf103 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Masaki Onoe und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Gastroenterology and Hepatology, Shimane University School of Medicine, Izumo, Shimane, Japan. Hauptthemen laut MEDLINE: Occupational Exposure, Endoscopy, Radiation Protection, Health Personnel. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 21 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background and aims: Healthcare professionals involved in fluoroscopy-guided endoscopy are occupationally exposed to ionizing radiation. We evaluated whether a patient-immobilization device, MEDO V-Fix®, reduces this exposure.

Methods

Monthly effective and lens equivalent dose were measured for nurses and doctors using personal dosemeters worn inside protective gear. Data from 7 months before and 10 months after device introduction were compared. Additionally a cost–benefit analysis (CBA) of dose reduction was performed.

Results

Monthly effective doses fell in both professions, but neither decline reached statistical significance. By contrast, nurses’ mean lens-equivalent dose dropped sharply from 35.0 to 6.5 μSv per procedure (P < 0.01), whereas the reduction in doctors was not significant. In the CBA, assuming a 5-y service life, the benefit-to-cost ratio ranged 1.02–2.72, indicating economic merit.

Conclusions

The MEDO V-Fix significantly reduces the occupational radiation exposure of endoscopy nurses and is a worthwhile investment from a CBA perspective.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Occupational ExposureEndoscopyRadiation ProtectionHealth PersonnelRadiation ExposureHumansFluoroscopyRadiation DosageCost-Benefit AnalysisRadiation Monitoring

Autor:innen und Institutionen

  • Department of Gastroenterology and Hepatology, Shimane University School of Medicine, Izumo, Shimane, Japan.
  • Department of Endoscopy, Shimane University Hospital, Izumo, Shimane, Japan.

ORCID-Profile: Masaki Onoe, Nobuhiko Fukuba, Yasuhide Kodama, Satoshi Kotani, Akihiko Oka, Naoki Oshima, Kousaku Kawashima, Norihisa Ishimura, Shunji Ishihara

Zitieren

APA

Onoe, M., Fukuba, N., Kodama, Y., Kotani, S., Oka, A., Oshima, N., Shibagaki, K., Kawashima, K., Ishimura, N., & Ishihara, S. (2025). Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf103

Vancouver

Onoe M, Fukuba N, Kodama Y, Kotani S, Oka A, Oshima N, et al. Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf103

BibTeX
@article{Onoe2025,
  author = {Onoe, Masaki and Fukuba, Nobuhiko and Kodama, Yasuhide and Kotani, Satoshi and Oka, Akihiko and Oshima, Naoki and Shibagaki, Kotaro and Kawashima, Kousaku and Ishimura, Norihisa and Ishihara, Shunji},
  title = {Impact of a patient fixation device on healthcare worker radiation doses in fluoroscopy-assisted endoscopy},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf103}
}
Kostenlos starten →