Optimizing z-axis coverage in computed tomography scans of the kidney, ureters, and bladder via standard operating procedures: a clinical audit report
Radiation Protection Dosimetry · 19.09.2025 · 201 (15) · 1059-1067
DOI: 10.1093/rpd/ncaf091 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 06.08.2025. Verfasst von Reinoud Maurits Blom und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Regional Hospital Heilig Hart Tienen, Kliniekstraat 45, Tienen 3300, Flanders, Belgium. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Urinary Bladder, Ureter, Kidney. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben.
Abstract (Originalsprache)
Internal audit at our radiology department identified variability in doses for computed tomography scans of the kidney, ureters, and bladder (CT KUB). This prompted a revision of the standard operating procedure (SOP) using less ambiguous osseous anatomical landmarks, namely the T10 vertebra endplate and inferior margin of the pubic symphysis. The objective of this study was to evaluate the use and effectiveness of SOPs as a means of scan length optimization and dose reduction. In total 247 CT-KUB scans were retrospectively analyzed in terms of compliance with the new osseous anatomical landmarks, and in terms of total scan length and dose-length product (DLP). The intervention comprised of two phases: (1) implementation of a new SOP with less ambiguous osseous anatomical landmarks, (2) amendment of the SOP, to assist identification of T10 endplate, by means of a sagittal scout view.This phased approach to SOP adjustments produced significant reduction in over-scanning. Excess over-scanning was reduced in the first phase, with a reduction of 14% in scan length and 32% in DLP. In the second phase, scan length was further reduced by 7%. Overall, scan length decreased by 20% and DLP by 55%.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, Regional Hospital Heilig Hart Tienen, Kliniekstraat 45, Tienen 3300, Flanders, Belgium.
- Department of Radiology, University Hospital Leuven, Herestraat 49, 3000 Leuven, Flanders, Belgium.
- Deptment of Imaging and Pathology, Medical Physics and Quality Assessment, Katholieke Universiteit Leuven, Herestraat 49, 3000 Leuven, Flanders, Belgium.
ORCID-Profile: Reinoud Maurits Blom
Zitieren
APA
Blom, R. M., Cockmartin, L., Marshall, N., & Bosmans, H. (2025). Optimizing z-axis coverage in computed tomography scans of the kidney, ureters, and bladder via standard operating procedures: a clinical audit report. Radiation Protection Dosimetry, 201(15), 1059-1067. https://doi.org/10.1093/rpd/ncaf091
Vancouver
Blom RM, Cockmartin L, Marshall N, Bosmans H. Optimizing z-axis coverage in computed tomography scans of the kidney, ureters, and bladder via standard operating procedures: a clinical audit report. Radiation Protection Dosimetry. 2025;201(15):1059-1067. doi:10.1093/rpd/ncaf091
BibTeX
@article{Blom2025,
author = {Blom, Reinoud Maurits and Cockmartin, Lesley and Marshall, Nicholas and Bosmans, Hilde},
title = {Optimizing z-axis coverage in computed tomography scans of the kidney, ureters, and bladder via standard operating procedures: a clinical audit report},
journal = {Radiation Protection Dosimetry},
year = {2025},
volume = {201},
number = {15},
pages = {1059--1067},
doi = {10.1093/rpd/ncaf091}
}
EUVIMED