EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access

Evaluation of positioning accuracy, radiation dose and image quality: artificial intelligence based automatic versus manual positioning for CT KUB

Souradip Kundu, Kaushik Nayak, Rajagopal Kadavigere, Saikiran Pendem iD, Priyanka iD

F1000Research · 2025

DOI: 10.12688/f1000research.150779.2 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift F1000Research, 2025. Verfasst von Souradip Kundu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, Ind…. Hauptthemen laut MEDLINE: Artificial Intelligence, Tomography, X-Ray Computed, Radiation Dosage, Patient Positioning. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Recent innovations are making radiology more advanced for patient and patient services. Under the immense burden of radiology practice, Artificial Intelligence (AI) assists in obtaining Computed Tomography (CT) images with less scan time, proper patient placement, low radiation dose (RD), and improved image quality (IQ). Hence, the aim of this study was to evaluate and compare the positioning accuracy, RD, and IQ of AI-based automatic and manual positioning techniques for CT kidney ureters and bladder (CT KUB).

Methods

This prospective study included 143 patients in each group who were referred for computed tomography (CT) KUB examination. Group 1 patients underwent manual positioning (MP), and group 2 patients underwent AI-based automatic positioning (AP) for CT KUB examination. The scanning protocol was kept constant for both the groups. The off-center distance, RD, and quantitative and qualitative IQ of each group were evaluated and compared.

Results

The AP group (9.66±6.361 mm) had significantly less patient off-center distance than the MP group (15.12±9.55 mm). There was a significant reduction in RD in the AP group compared with that in the MP group. The quantitative image noise (IN) was lower, with a higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the AP group than in the MP group (p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial IntelligenceTomography, X-Ray ComputedRadiation DosagePatient PositioningUrinary BladderUreterHumansFemaleMaleMiddle AgedAgedAdultProspective StudiesKidneyAutomation

Stichwörter der Autor:innen

Artificial IntelligenceComputed TomographyImage qualityPositioning accuracyRadiation dose

Autor:innen und Institutionen

  • Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
  • Department of Radio Diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.

ORCID-Profile: Saikiran Pendem, Priyanka

Zitieren

APA

Kundu, S., Nayak, K., Kadavigere, R., Pendem, S., & Priyanka (2025). Evaluation of positioning accuracy, radiation dose and image quality: artificial intelligence based automatic versus manual positioning for CT KUB. F1000Research. https://doi.org/10.12688/f1000research.150779.2

Vancouver

Kundu S, Nayak K, Kadavigere R, Pendem S, Priyanka. Evaluation of positioning accuracy, radiation dose and image quality: artificial intelligence based automatic versus manual positioning for CT KUB. F1000Research. 2025. doi:10.12688/f1000research.150779.2

BibTeX
@article{Kundu2025,
  author = {Kundu, Souradip and Nayak, Kaushik and Kadavigere, Rajagopal and Pendem, Saikiran and Priyanka},
  title = {Evaluation of positioning accuracy, radiation dose and image quality: artificial intelligence based automatic versus manual positioning for CT KUB},
  journal = {F1000Research},
  year = {2025},
  doi = {10.12688/f1000research.150779.2}
}
Kostenlos starten →