Vergleichsstudie in der Zeitschrift F1000Research, 2025. Verfasst von Souradip Kundu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, Ind…. Hauptthemen laut MEDLINE: Artificial Intelligence, Tomography, X-Ray Computed, Radiation Dosage, Patient Positioning. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Recent innovations are making radiology more advanced for patient and patient services. Under the immense burden of radiology practice, Artificial Intelligence (AI) assists in obtaining Computed Tomography (CT) images with less scan time, proper patient placement, low radiation dose (RD), and improved image quality (IQ). Hence, the aim of this study was to evaluate and compare the positioning accuracy, RD, and IQ of AI-based automatic and manual positioning techniques for CT kidney ureters and bladder (CT KUB).
Methods
This prospective study included 143 patients in each group who were referred for computed tomography (CT) KUB examination. Group 1 patients underwent manual positioning (MP), and group 2 patients underwent AI-based automatic positioning (AP) for CT KUB examination. The scanning protocol was kept constant for both the groups. The off-center distance, RD, and quantitative and qualitative IQ of each group were evaluated and compared.
Results
The AP group (9.66±6.361 mm) had significantly less patient off-center distance than the MP group (15.12±9.55 mm). There was a significant reduction in RD in the AP group compared with that in the MP group. The quantitative image noise (IN) was lower, with a higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the AP group than in the MP group (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
- Department of Radio Diagnosis and Imaging, Kasturba Medical College, Manipal Academy of Higher Education, Manipal, Karnataka, 576104, India.
ORCID-Profile: Saikiran Pendem, Priyanka
Zitieren
APA
Kundu, S., Nayak, K., Kadavigere, R., Pendem, S., & Priyanka (2025). Evaluation of positioning accuracy, radiation dose and image quality: artificial intelligence based automatic versus manual positioning for CT KUB. F1000Research. https://doi.org/10.12688/f1000research.150779.2
Vancouver
Kundu S, Nayak K, Kadavigere R, Pendem S, Priyanka. Evaluation of positioning accuracy, radiation dose and image quality: artificial intelligence based automatic versus manual positioning for CT KUB. F1000Research. 2025. doi:10.12688/f1000research.150779.2
BibTeX
@article{Kundu2025,
author = {Kundu, Souradip and Nayak, Kaushik and Kadavigere, Rajagopal and Pendem, Saikiran and Priyanka},
title = {Evaluation of positioning accuracy, radiation dose and image quality: artificial intelligence based automatic versus manual positioning for CT KUB},
journal = {F1000Research},
year = {2025},
doi = {10.12688/f1000research.150779.2}
}
EUVIMED