Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2025. Verfasst von Dmitry Nemirovsky und 8 weiteren Autor:innen. Beteiligte Einrichtung: Physics Unit, Sami Shamoon College of Engineering, Ashdod 77245, Israel. Hauptthemen laut MEDLINE: Lithium Compounds, Fluorides, Magnesium, Titanium. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Unified Interaction Model (UNIM) is reformulated to include recent advances in the understanding of the role of spatial correlations leading to localized and delocalized recombination in LiF:Mg,Ti and to the correlation between the optical absorption bands and the glow peaks of composite peak 5. The reformulated UNIM is applied to the simulation of the linear/supralinear dose response and to calculations of the dose threshold, Dc, of supralinear behaviour and to the deviations from linearity in the dose range from 0.1 to 10 Gy.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lithium CompoundsFluoridesMagnesiumTitaniumComputer SimulationRadiation DosageHumansDose-Response Relationship, RadiationLinear Models

Substanzen

lithium fluorideLithium CompoundsFluoridesMagnesiumTitanium

Autor:innen und Institutionen

  • Physics Unit, Sami Shamoon College of Engineering, Ashdod 77245, Israel.
  • Physics Unit, Sami Shamoon College of Engineering, Be'er Sheva 84108, Israel.
  • Physics Department, Ben Gurion University of the Negev, Be'er Sheva 84105, Israel.
  • Soreq Nuclear Research Center, Yavne 81800, Israel.
  • School of Physics, University of Wollongong, NSW 2522, Australia.

Zitieren

APA

Nemirovsky, D., Oster, L., Horowitz, Y. S., Reshes, G., Biderman, S., Eliyahu, I., Einav, H., Herman, B., & Shapiro, A. (2025). The reformulated unified interaction model: simulations of linear/supralinear dose reponse in LiF:Mg,Ti, dose threshold for appearance of supralinearity and deviations from linearity in the dose range 0.1–10 Gy. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncaf058

Vancouver

Nemirovsky D, Oster L, Horowitz YS, Reshes G, Biderman S, Eliyahu I, et al. The reformulated unified interaction model: simulations of linear/supralinear dose reponse in LiF:Mg,Ti, dose threshold for appearance of supralinearity and deviations from linearity in the dose range 0.1–10 Gy. Radiation Protection Dosimetry. 2025. doi:10.1093/rpd/ncaf058

BibTeX
@article{Nemirovsky2025,
  author = {Nemirovsky, Dmitry and Oster, Leonid and Horowitz, Yigal S and Reshes, Galina and Biderman, Shlomo and Eliyahu, Ilan and Einav, Hezy and Herman, Beny and Shapiro, Alex},
  title = {The reformulated unified interaction model: simulations of linear/supralinear dose reponse in LiF:Mg,Ti, dose threshold for appearance of supralinearity and deviations from linearity in the dose range 0.1–10 Gy},
  journal = {Radiation Protection Dosimetry},
  year = {2025},
  doi = {10.1093/rpd/ncaf058}
}
Kostenlos starten →