The out-of-plane contact shield and mA-modulation – the effect on fetal absorbed dose
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae204 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Heli R S Larjava und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medical Physics and Department of Radiology, Turku University Hospital and University of Turku, 20521 Turku, Finland. Hauptthemen laut MEDLINE: Phantoms, Imaging, Radiation Dosage, Fetus, Radiation Protection. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: State Research Funding of the Turku University Hospital.
Abstract (Originalsprache)
The effect of patient shielding on fetal radiation dose was evaluated in computed tomography pulmonary angiography with the out-of-plane shield visible in the localizer but absent in the scan range in chest computed tomography (CT). An anthropomorphic phantom with additional prosthetic pregnancy belly was scanned with different CT scanners using clinical imaging protocols and radiophotoluminescence dosemeters (GD-352 M). The out-of-plane shield decreased the fetal absorbed radiation dose with Siemens Somatom go.Up, Canon Aquilion Prime SP and Canon Aquilion One scanners. The decrease was 3.9%–39.4% (0.01–0.09 mGy). With GE Optima the shield increased the fetal dose by 100% (0.23 mGy), with Canon Aquilion One and GE Optima scanners the abdomen dose increase was 17.5% and 36.4%, respectively (0.61 and 1.38 mGy). Applying an out-of-plane shield outside the scanned volume may increase the fetal radiation dose during CT when using tube current modulation, depending on the make and model of the CT scanner.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Medical Physics and Department of Radiology, Turku University Hospital and University of Turku, 20521 Turku, Finland.
- Department of Medical Physics, Turku University Hospital and University of Turku, 20521 Turku, Finland.
- Department of Radiology, Turku University Hospital and University of Turku, 20521 Turku, Finland.
ORCID-Profile: Heli R S Larjava
Förderung
- State Research Funding of the Turku University Hospital
Zitieren
APA
Larjava, H. R. S., Eneh, C. T. M., Saikkonen, A., & Parkkola, R. K. (2024). The out-of-plane contact shield and mA-modulation – the effect on fetal absorbed dose. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae204
Vancouver
Larjava HRS, Eneh CTM, Saikkonen A, Parkkola RK. The out-of-plane contact shield and mA-modulation – the effect on fetal absorbed dose. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae204
BibTeX
@article{Larjava2024,
author = {Larjava, Heli R S and Eneh, Chibuzor T M and Saikkonen, Aleksi and Parkkola, Riitta K},