From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae202 ↗Kurz gefasst
Studienprotokoll in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Liwei Hu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, …. Hauptthemen laut MEDLINE: Radiation Dosage, Head, Tomography, X-Ray Computed. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Shanghai Committee of Science and Technology, National Natural Science Foundation of China, National Key Clinical Specialties Construction Program.
Abstract (Originalsprache)
This study proposes a practical approach to assessing the need for and determining the transitioning parameters from age-specific to size-specific dose protocols in paediatric head computed tomography examinations. It was designed to begin with the two different age-specific protocols currently applied on paediatric patients of 1 y ≤ age ≤ 6 y (21.34 mGy) and those of age >6 y (34.73 mGy). One characteristic size (HDthreshold) was found by measuring anteroposterior head diameter on historical topograms and used with age to set 135 cases into four groups for investigation (A, ≤6y, ≤HDthreshold; B, ≤6y, >HDthreshold; C, >6y, ≤HDthreshold; and D, >6 y, >HDthreshold). The image quality was compared in both subjective and objective manners. Results suggest patients in Group C may have received a potential overdose (38%), while the exposure setting for Group D may replace that for B. The proposed strategy was sufficient to assess the necessity and determine the transitioning parameters from age- to size-specific dose protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiology, Shanghai Children's Medical Center, School of Medicine, Shanghai Jiao Tong University, 1678 Dongfang Road, Shanghai 200127, China.
- Pediatric Imaging Advanced Technology Research Center, 1678 Dongfang Road, Shanghai 200127, China.
- United Imaging Healthcare, 2258 Chengbei Road, Shanghai 201815, China.
ORCID-Profile: Guozhi Zhang, Qian Wang
Förderung
- Shanghai Committee of Science and Technology
- National Natural Science Foundation of China
- National Key Clinical Specialties Construction Program
Zitieren
APA
Hu, L., Ouyang, R., Li, J., Zhang, G., Li, J., Guo, C., Wang, Q., & Zhong, Y. (2024). From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae202
Vancouver
Hu L, Ouyang R, Li J, Zhang G, Li J, Guo C, et al. From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae202
BibTeX
@article{Hu2024,
author = {Hu, Liwei and Ouyang, Rongzhen and Li, Jing and Zhang, Guozhi and Li, Jiong and Guo, Chen and Wang, Qian and Zhong, Yumin},
title = {From age-specific to size-specific dose protocol for paediatric head computed tomography: a simple practical strategy for necessity assessment and parameter setting},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae202}
}
EUVIMED