ESR measurement of carbonated hydroxyapatite for dosemeter
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncae147 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Hajime Seito und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Advanced Quantum Beam Technology, Takasaki Institute for Advanced Quantum Science, National Institutes for Quantum Science and Technolo…. Hauptthemen laut MEDLINE: Durapatite, Gamma Rays. Die Arbeit nennt 11 Literaturangaben.
Abstract (Originalsprache)
We have examined a dosimetry characteristic of carbonate hydroxyapatite (CO3HAp), which is a dental bone graft material. The purpose of this work is to investigate the reproducibility and stability of radiation-induced radicals on CO3HAp samples and assess the feasibility of using these materials as dosemeters. CO3HAp samples were exposed to gamma rays with dose range from 10 to 10 000 Gy. The electron spin resonance (ESR) spectra for irradiated samples were measured. Variation of peak-to-peak amplitude of the ESR signal intensity as a function of absorbed dose for CO3HAp was compared with that for alanine dosemeters, suggesting that the CO3HAp sample has a good linear dose response in the range from 10 to 10 000 Gy as well as does the alanine dosemeters.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Advanced Quantum Beam Technology, Takasaki Institute for Advanced Quantum Science, National Institutes for Quantum Science and Technology (QST), 1233 Watanuki-cho, Takasaki, Gunma 370-1292, Japan.
- Research Group For Nuclear Chemistry, Nuclear Science and Engineering Center, Japan Atomic Energy Agency (JAEA), 2-4 Shirakata, Tokai-mura, Ibaraki, Naka-gun 319-1195, Japan.
ORCID-Profile: Hajime Seito, Toshitaka Oka
Zitieren
APA
Seito, H., Yokozuka, E., Oka, T., Kitatsuji, Y., & Nagasawa, N. (2024). ESR measurement of carbonated hydroxyapatite for dosemeter. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae147
Vancouver
Seito H, Yokozuka E, Oka T, Kitatsuji Y, Nagasawa N. ESR measurement of carbonated hydroxyapatite for dosemeter. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae147
BibTeX
@article{Seito2024,
author = {Seito, Hajime and Yokozuka, Eri and Oka, Toshitaka and Kitatsuji, Yoshihiro and Nagasawa, Naotsugu},
title = {ESR measurement of carbonated hydroxyapatite for dosemeter},