Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Tarika Thumvijit und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai 50200, Thailand. Hauptthemen laut MEDLINE: Air Pollution, Indoor, Radon, Air Pollutants, Radioactive, Radiation Monitoring. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 13 Literaturangaben.
Abstract (Originalsprache)
This study aimed to determine the annual effective dose resulting from radon and thoron progeny inhalation. The levels of radon, thoron, and progeny were assessed in residences situated in the Doi Lo region of Chiang Mai, Thailand. Indoor radon and thoron concentrations were detected using passive discriminative detectors. Using a progeny deposition rate detector, this study evaluates radon and thoron progeny [equilibrium-equivalent radon concentration (EERC) for radon and equilibrium-equivalent thoron concentration (EETC) for thoron]. Data were collected from 44 dwellings between March and May 2020. The results found that indoor radon concentrations ranged from 17 to 118 Bq m−3, while thoron concentrations ranged from 12 to 72 Bq m−3. The radon progeny (EERC) ranged from 4 to 173 Bq m−3, whereas thoron progeny (EETC) ranged from 1 to 15 Bq m−3. The total annual effective dose received from radon and thoron progeny inhalation varied from 0.5 to 5 mSv y−1.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai 50200, Thailand.
- Center of Radiation Research and Medical Imaging, Chiang Mai University, Chiang Mai 50200 Thailand.
- Natural Radiation Survey and Analysis Research Unit, Chulalongkorn University, Bangkok 10330 Thailand.
- Department of Radiation Physics, Institution of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Aomori 036-8564, Japan.
- Department of Nuclear Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok 10330 Thailand.
ORCID-Profile: Tarika Thumvijit, Shinji Tokonami
Zitieren
APA
Thumvijit, T., Somboon, S., Tapanya, M., Ruktinnakorn, K., Kranrod, C., Tokonami, S., Chanyotha, S., & Sriburee, S. (2024). Assessment of annual effective doses from indoor radon and thoron in Doi Lo, Chiang Mai, Thailand. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae130
Vancouver
Thumvijit T, Somboon S, Tapanya M, Ruktinnakorn K, Kranrod C, Tokonami S, et al. Assessment of annual effective doses from indoor radon and thoron in Doi Lo, Chiang Mai, Thailand. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae130
BibTeX
@article{Thumvijit2024,
author = {Thumvijit, Tarika and Somboon, Siriprapa and Tapanya, Monruedee and Ruktinnakorn, Kewalin and Kranrod, Chutima and Tokonami, Shinji and Chanyotha, Supitcha and Sriburee, Sompong},
title = {Assessment of annual effective doses from indoor radon and thoron in Doi Lo, Chiang Mai, Thailand},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncae130}
}
EUVIMED