EUVIMEDEUVIMED entdecken
Crossref

Effective dose assessment due to inhalation of 222Rn, 220Rn, and their progeny: highlighting the major contribution of thoron in a thoron-prone area in Cameroon

Léonard Boris Djeufack, Issa Hamadou, Chutima Kranrod, Rosaline Mishra, Masahiro Hosoda, Balvinder K Sapra, Saïdou, Shinji Tokonami

Radiation and Environmental Biophysics · 2024

DOI: 10.1007/s00411-024-01082-3 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation and Environmental Biophysics, 2024. Verfasst von Léonard Boris Djeufack und 7 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Physics Laboratory, Faculty of Science, University of Yaoundé I, P.O. Box 812, Yaoundé, Cameroon. Hauptthemen laut MEDLINE: Radon, Air Pollutants, Radioactive, Air Pollution, Indoor, Radon Daughters. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 53 Literaturangaben. Gefördert von: Ministry of Scientific Research and Innovation, Cameroon, Hirosaki University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To assess public exposure to radon, thoron, and their progeny, measurements were conducted in 50 dwellings within the bauxite-rich area of Fongo-Tongo in western Cameroon. Passive integrating radon-thoron discriminative detectors (specifically RADUET) were employed for radon and thoron measurements. Additionally, concentrations of short-lived radon and thoron progeny were estimated using Direct Radon Progeny Sensors (DRPSs) and Direct Thoron Progeny Sensors (DTPSs) based on LR-115 detectors. The findings revealed indoor radon concentrations ranging from 31 to 123 Bq m-3 with a geometric mean (GM) of 62 Bq m-3, and indoor thoron concentrations ranging from 36 to 688 Bq m-3 with a GM of 242 Bq m-3. The Equilibrium Equivalent Radon Concentration (EERC) ranged from 3 to 86 Bq m-3 with a GM of 25 Bq m-3, while the Equilibrium Equivalent Thoron Concentration (EETC) ranged from 1.2 to 12.5 Bq m-3 with a GM of 7.6 Bq m-3. Notably, all dwellings recorded radon concentrations below 100 Bq m-3. Arithmetic means of radon and thoron equilibrium factors were calculated as 0.47 and 0.04, respectively. To assess annual effective doses from radon and thoron inhalation, equilibrium factors were used along with direct measurements of EERC and EETC. The differences observed in annual effective doses were 4.5% for radon and 42.5% for thoron. Furthermore, the contribution of thoron and its decay products to the annual effective dose from radon, thoron, and their progeny ranged from 12 to 94%, with an average contribution of 58%. Thus, this study found that the effective dose due to thoron inhalation in the study area exceeded that due to radon inhalation. It is concluded that, when evaluating radiation doses and health risks, it is crucial to consider both thoron and its progeny alongside radon and its progeny. This underscores the importance of considering direct measurements for accurately estimating radiation doses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadonAir Pollutants, RadioactiveAir Pollution, IndoorRadon DaughtersRadiation MonitoringRadiation DosageCameroonHumansHousing

Stichwörter der Autor:innen

Equilibrium factorInhalation doseProgenyRadonThoron

Substanzen

RadonAir Pollutants, RadioactiveRadon DaughtersRadon-222Radon-220

Autor:innen und Institutionen

  • Nuclear Physics Laboratory, Faculty of Science, University of Yaoundé I, P.O. Box 812, Yaoundé, Cameroon.
  • Research Centre for Nuclear Science and Technology, Institute of Geological and Mining Research, P.O. Box 4110, Yaoundé, Cameroon.
  • National Advanced School of Mines and Petroleum Industries, University of Maroua, P.O. Box 08, Kaélé, Cameroon.
  • Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki City, Aomori, 036-8564, Japan.
  • Radiological Physics and Advisory Division, Bhabha Atomic Research Center, Mumbai, 400 085, India.
  • Department of Radiation Science, Hirosaki University Graduate School of Health Sciences, Hirosaki City, Aomori, Japan.

Förderung

  • Ministry of Scientific Research and Innovation, Cameroon
  • Hirosaki University

Zitieren

APA

Djeufack, L. B., Hamadou, I., Kranrod, C., Mishra, R., Hosoda, M., Sapra, B. K., Saïdou, & Tokonami, S. (2024). Effective dose assessment due to inhalation of 222Rn, 220Rn, and their progeny: highlighting the major contribution of thoron in a thoron-prone area in Cameroon. Radiation and Environmental Biophysics. https://doi.org/10.1007/s00411-024-01082-3

Vancouver

Djeufack LB, Hamadou I, Kranrod C, Mishra R, Hosoda M, Sapra BK, et al. Effective dose assessment due to inhalation of 222Rn, 220Rn, and their progeny: highlighting the major contribution of thoron in a thoron-prone area in Cameroon. Radiation and Environmental Biophysics. 2024. doi:10.1007/s00411-024-01082-3

BibTeX
@article{Djeufack2024,
  author = {Djeufack, Léonard Boris and Hamadou, Issa and Kranrod, Chutima and Mishra, Rosaline and Hosoda, Masahiro and Sapra, Balvinder K and Saïdou and Tokonami, Shinji},
  title = {Effective dose assessment due to inhalation of 222Rn, 220Rn, and their progeny: highlighting the major contribution of thoron in a thoron-prone area in Cameroon},
  journal = {Radiation and Environmental Biophysics},
  year = {2024},
  doi = {10.1007/s00411-024-01082-3}
}
Kostenlos starten →