Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Madalakote Rajanna Ambika und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physics, MS Ramaiah Institute of Technology, Bengaluru 560054, India. Hauptthemen laut MEDLINE: Polymers, Molybdenum, Bismuth. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 27 Literaturangaben. Gefördert von: Ramaiah Institute of Technology.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Polydimethyl silicone rubber-based polymer composites filled with molybdenum and bismuth were fabricated using simple open mold cast technique. The physical and chemical structure and gamma shielding parameters like attenuation coefficient, half-value layer (HVL) thickness and relaxation length have been investigated for the said novel materials using X-ray diffraction (XRD), Fourier transform Infrared spectroscopy (FTIR) and gamma ray spectrometer. XRD study reveals the crystalline nature of the composites. It is evident from FTIR studies that there is no chemical interaction between the polymer matrix and filler particles. The results of attenuation studies reveal that the linear attenuation coefficient increases with addition of Bi and Mo and is found to be 0.653, 1.341 and 1.017, 1.793 and 0.102, 0.152 cm−1 for 1MMB and 2MMB polymer composites at 80, 356 and 662 keV gamma rays, respectively. The HVL thickness of the materials is found to be 1.06, 0.51 and 0.68, 0.38 and 6.73, 4.532 cm for 1MMB (20Mo + 10Bi phr) and 2MMB (40Mo + 20Bi phr) at these energies, respectively. The mass attenuation coefficient of the novel composites 1MMB and 2MMB is found to be higher than the conventional materials like lead and barite for 356 keV gamma rays. In addition, the material is found to be light weight and flexible enabling to be molded in required forms, thus being a substitute for the material lead that is known to be heavy and toxic by nature.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PolymersMolybdenumBismuthGamma RaysRadiation, IonizingRadiation ProtectionMaterials TestingSpectroscopy, Fourier Transform InfraredX-Ray DiffractionHumans

Substanzen

PolymersMolybdenumBismuth

Autor:innen und Institutionen

  • Department of Physics, MS Ramaiah Institute of Technology, Bengaluru 560054, India.
  • Department of Physics, Bangalore University, JB Campus, Bengaluru 560056, India.
  • Radiation Safety Systems Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400085, India.

ORCID-Profile: Sherry S Kuttukaran

Förderung

  • Ramaiah Institute of Technology

Zitieren

APA

Rajanna Ambika, M., Kuttukaran, S. S., Nagaiah, N., Melavanki, R., Shashi Kumar, S. K., & Kumar Suman, S. (2024). Multifiller-based polymer composites for shielding high energy ionising radiation. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncae010

Vancouver

Rajanna Ambika M, Kuttukaran SS, Nagaiah N, Melavanki R, Shashi Kumar SK, Kumar Suman S. Multifiller-based polymer composites for shielding high energy ionising radiation. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncae010

BibTeX
@article{RajannaAmbika2024,
  author = {Rajanna Ambika, Madalakote and Kuttukaran, Sherry S and Nagaiah, Ningaiah and Melavanki, Raveendra and Shashi Kumar, Shivappa K and Kumar Suman, Santosh},
  title = {Multifiller-based polymer composites for shielding high energy ionising radiation},
  journal = {Radiation Protection Dosimetry},
  year = {2024},
  doi = {10.1093/rpd/ncae010}
}
Kostenlos starten →