EUVIMEDEUVIMED entdecken
Crossref

Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi2O3 additive fillers

Nutthapong Moonkum, Aksarapak Thawornnittayakul, Gunjanaporn Tochaikul

Radiation and Environmental Biophysics · 2026-03 · 65 (1) · 587-596

DOI: 10.1007/s00411-025-01166-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation and Environmental Biophysics, online erschienen am 13.11.2025. Verfasst von Nutthapong Moonkum und 2 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Radiological Technology, Rangsit University, Pathumthani, 12000, Thailand. Hauptthemen laut MEDLINE: Bismuth, Gamma Rays, Radiation Protection, Epoxy Resins. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 31 Literaturangaben. Gefördert von: National Research Council of Thailand (NRCT), Research Institute of Rangsit University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Owing to the use of highly penetrating gamma radiation for medical proposes, radiation shielding is a crucial issue for radiological protection. Lead-free shielding materials are becoming more interesting to solve the disadvantages of lead (i.e., toxicity and heaviness). This study investigates the radiation shielding performance of epoxy resin (ER) and Portland cement (PC) composites enriched with bismuth oxide (Bi2O3) fillers at weight ratios of 20%, 30%, 40%, and 50%, across photon energies ranging from 122 to 662 keV. The results indicate that higher Bi2O3 content enhances the linear attenuation coefficient (0.299 to 1.187 cm- 1), radiation protection efficiency (26 to 99%) and lead-equivalent thickness (0.16 to 2.1 cm), demonstrating improved radiation attenuation ability. The transmission factor (TF) was calculated for four different thicknesses of each composite, showing that thicker samples resulted in lower TF values (0.86%) compared to thinner ones (74.16%). Despite being thicker than the standard lead shielding; the composites are half of the weight. Among all tested samples, the ER/Bi50 composite demonstrated the most effective shielding potential. While no full economic or life cycle assessment was conducted, the use of non-toxic components and reduced weight suggests that ER/Bi50 may offer potential advantages in terms of cost-effectiveness and environmental friendliness. Thus, ER/Bi50 with 4 cm thickness is proposed as a promising lead-free alternative to conventional lead-based shielding materials for gamma ray attenuation in medical applications at energies below 356 keV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BismuthGamma RaysRadiation ProtectionEpoxy ResinsConstruction MaterialsMaterials Testing

Stichwörter der Autor:innen

Bismuth oxideEpoxy resinGamma rayPortland cementRadiation shielding material

Substanzen

BismuthEpoxy Resinsbismuth oxide

Autor:innen und Institutionen

  • Faculty of Radiological Technology, Rangsit University, Pathumthani, 12000, Thailand.
  • Faculty of Radiological Technology, Rangsit University, Pathumthani, 12000, Thailand. gunjanaporn.t@rsu.ac.th.

Förderung

  • National Research Council of Thailand (NRCT)
  • Research Institute of Rangsit University

Zitieren

APA

Moonkum, N., Thawornnittayakul, A., & Tochaikul, G. (2026). Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi2O3 additive fillers. Radiation and Environmental Biophysics, 65(1), 587-596. https://doi.org/10.1007/s00411-025-01166-8

Vancouver

Moonkum N, Thawornnittayakul A, Tochaikul G. Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi2O3 additive fillers. Radiation and Environmental Biophysics. 2026;65(1):587-596. doi:10.1007/s00411-025-01166-8

BibTeX
@article{Moonkum2026,
  author = {Moonkum, Nutthapong and Thawornnittayakul, Aksarapak and Tochaikul, Gunjanaporn},
  title = {Evaluation of the gamma radiation shielding performance of epoxy resin and Portland cement-based composites enriched with Bi2O3 additive fillers},
  journal = {Radiation and Environmental Biophysics},
  year = {2026},
  volume = {65},
  number = {1},
  pages = {587--596},
  doi = {10.1007/s00411-025-01166-8}
}
Kostenlos starten →