Occupational internal monitoring in nuclear medicine service of Sainte-Anne military hospital: previous considerations and results
Radiation Protection Dosimetry · 2024
DOI: 10.1093/rpd/ncad307 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2024. Verfasst von Héloïse Gervot und 6 weiteren Autor:innen. Beteiligte Einrichtung: Laboratoire d'analyses de surveillance et d'expertise de la Marine, BCRM Toulon - LASEM BP61, 83800 Toulon Cedex 9, France. Hauptthemen laut MEDLINE: Nuclear Medicine, Occupational Exposure, Radiation Monitoring. Die Arbeit nennt 15 Literaturangaben.
Abstract (Originalsprache)
The Nuclear Medicine Department of Sainte-Anne military hospital in Toulon uses 99mTc, 123I and 18F unsealed sources to provide therapeutic and diagnostic care. For a few years, only ambient air and surface monitoring were performed to check the absence of internal contamination risk for workers. To verify this risk assessment hypothesis, confirmatory monitoring programme including in vivo and in vitro measurements was performed by the French defence radiation protection service (SPRA, Clamart). Here, due to the short half-life of targeted radionuclides, the analytical sensitivity was determined with estimations of minimal detectable activities and derived recording levels. It was shown that sensitivity was sufficient to detect an internal contamination leading to an effective dose of 0.1 mSv for few days post intake. At the same time, around 20 whole-body countings were performed. Results were below minimal detectable activity and were confirmed by 24-hours urine analysis. So, actual working conditions do not lead to measurable internal contamination for nuclear medicine staff.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Laboratoire d'analyses de surveillance et d'expertise de la Marine, BCRM Toulon - LASEM BP61, 83800 Toulon Cedex 9, France.
- Institut de recherches biomédicales des armées, Place Général Valérie André, 91220 Brétigny-sur-Orge, France.
- Service de Protection Radiologique des Armées, 1bis rue du Lieutenant Raoul Batany CS, 557 92141 Clamart Cedex, France.
- Hôpital d'instruction des armées Sainte-Anne, BCRM Toulon, BP600 Toulon Cedex 9, France.
ORCID-Profile: Héloïse Gervot
Zitieren
APA
Gervot, H., Letessier, W., Loess, J., Bayle-Escurat, C., Métivier, D., Saurat, D., & Jamet-Anselme, E. (2024). Occupational internal monitoring in nuclear medicine service of Sainte-Anne military hospital: previous considerations and results. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad307
Vancouver
Gervot H, Letessier W, Loess J, Bayle-Escurat C, Métivier D, Saurat D, et al. Occupational internal monitoring in nuclear medicine service of Sainte-Anne military hospital: previous considerations and results. Radiation Protection Dosimetry. 2024. doi:10.1093/rpd/ncad307
BibTeX
@article{Gervot2024,
author = {Gervot, Héloïse and Letessier, Wilfried and Loess, Jérôme and Bayle-Escurat, Christopher and Métivier, Denis and Saurat, Dominique and Jamet-Anselme, Emilie},
title = {Occupational internal monitoring in nuclear medicine service of Sainte-Anne military hospital: previous considerations and results},
journal = {Radiation Protection Dosimetry},
year = {2024},
doi = {10.1093/rpd/ncad307}
}