A silicon photomultiplier based compact gamma spectrometer for environmental gamma radiation monitoring networks

Saurabh Srivastava iD, Pratip Mitra iD, Amit Kumar, Mohit Tyagi, Aerattukkara Vinod Kumar, Anita Topkar

Radiation Protection Dosimetry · 29.12.2023 · 200 (1) · 1-11

DOI: 10.1093/rpd/ncad256 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, online erschienen am 14.09.2023. Verfasst von Saurabh Srivastava und 5 weiteren Autor:innen. Beteiligte Einrichtung: Environmental Monitoring and Assessment Division, Bhabha Atomic Research Centre, Mumbai 400085, India. Hauptthemen laut MEDLINE: Cesium Radioisotopes, Radiation Monitoring. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben. Gefördert von: Department of Atomic Energy, Government of India.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this paper, the details of the development and performance characterisation of a compact, low-power gamma spectrometer for environmental gamma radiation monitoring networks are presented. To reduce the power consumption and the size of the spectrometer, a gamma detector comprising a silicon photomultiplier coupled to a Gd3Ga3Al2O12:Ce,B (GGAG:Ce,B) scintillator has been used for gamma spectrometry. Initially, a Monte Carlo simulation study was carried out to verify the suitability of the 5 mm × 5 mm × 5 mm GGAG:Ce,B crystal for spectrometry of gamma sources in the energy range 60–1332 keV. For minimising the power consumption, the signal processing electronics has been custom designed. This electronics was realised using standard off-the-shelf components to reduce the cost. The developed spectrometer is of size 16 cm × 10 cm × 6 cm, weighs 600 g and consumes 600 mW power. The spectrometer is developed such that it could be directly interfaced with GSM/Xbee for wireless communication with the radiation monitoring networks. The lower-level discriminator threshold of the system is 40 keV and the total electronic noise is <20 keV. The experimentally measured sensitivity of the spectrometer for 137Cs (662 keV) is 2.4 cps/μGy/h at 3.5 V overvoltage. The spectrometer offers excellent linearity over the measured energy range of 60–1332 keV and an energy resolution of ~10% for 662 keV gamma-ray at room temperature.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cesium RadioisotopesRadiation MonitoringGamma RaysComputer Simulation

Substanzen

Cesium-137Cesium Radioisotopes

Autor:innen und Institutionen

  • Environmental Monitoring and Assessment Division, Bhabha Atomic Research Centre, Mumbai 400085, India.
  • Homi Bhabha National Institute, Mumbai 400094, India.
  • Electronics Division, Bhabha Atomic Research Centre, Mumbai 400085, India.
  • Technical Physics Division, Bhabha Atomic Research Centre, Mumbai 400085, India.

ORCID-Profile: Saurabh Srivastava, Pratip Mitra

Förderung

  • Department of Atomic Energy, Government of India

Zitieren

APA

Srivastava, S., Mitra, P., Kumar, A., Tyagi, M., Kumar, A. V., & Topkar, A. (2023). A silicon photomultiplier based compact gamma spectrometer for environmental gamma radiation monitoring networks. Radiation Protection Dosimetry, 200(1), 1-11. https://doi.org/10.1093/rpd/ncad256

Vancouver

Srivastava S, Mitra P, Kumar A, Tyagi M, Kumar AV, Topkar A. A silicon photomultiplier based compact gamma spectrometer for environmental gamma radiation monitoring networks. Radiation Protection Dosimetry. 2023;200(1):1-11. doi:10.1093/rpd/ncad256

BibTeX
@article{Srivastava2023,
  author = {Srivastava, Saurabh and Mitra, Pratip and Kumar, Amit and Tyagi, Mohit and Kumar, Aerattukkara Vinod and Topkar, Anita},
  title = {A silicon photomultiplier based compact gamma spectrometer for environmental gamma radiation monitoring networks},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  volume = {200},
  number = {1},
  pages = {1--11},
  doi = {10.1093/rpd/ncad256}
}
Kostenlos starten →