EUVIMEDEUVIMED entdecken
Crossref

γ-H2AX and phospho-ATM enzyme-linked immunosorbent assays as biodosimetry methods for radiation exposure assessment: a pilot study

Dwi Ramadhani iD, Devita Tetriana, Sofiati Purnami, Viria Agesti Suvifan, Iin Kurnia Hasan Basri, Teja Kisnanto, Tiara Andalya Oktariyani, Dira Syafira, Muhamad Yasin Yunus, Tomisato Miura iD, Mukh Syaifudin, Retno Widowati

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncad253 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Dwi Ramadhani und 11 weiteren Autor:innen. Beteiligte Einrichtung: Research Center for Radioisotope, Radiopharmaceutical and Biodosimetry Technology, Research Organization for Nuclear Energy, National Research and In…. Hauptthemen laut MEDLINE: Histones, Radiation Exposure. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Gefördert von: Environmental Radioactivity Research Network Center.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In the event of a radiological incident, a fast and accurate biological dosimetry (biodosimetry) method for evaluating people who have been potentially exposed to ionising radiation is crucial. Among the many biodosimetry methods available, the immunodetection of phosphorylated H2AX (γ-H2AX) stands as a promising method to be used in the triage of patients exposed to radiation. Currently, the most common way to measure γ-H2AX levels is through fluorescence microscopy. In this pilot study, we assessed the feasibility of using an enzyme-linked immunosorbent assay (ELISA) for quantifying γ-H2AX for biodosimetry purposes. Moreover, the usefulness of measuring phosphorylated ATM (pATM) levels through ELISA for biodosimetry was also evaluated. Blood samples were obtained from three male donors (38 y) and were irradiated with 60Co (0, 1, 2 and 6 Gy). Peripheral blood mononuclear cells (PBMCs) were isolated and lysed before measuring γ-H2AX, total H2AX protein and pATM using ELISA kits. The dicentric chromosome assay (DCA) using whole blood was also performed for comparison. Data from all donors at each dose were pooled before statistical analysis. The ratio of γ-H2AX/total H2AX and pATM levels increased in a radiation-dose-dependent manner. The average γ-H2AX/total H2AX ratios were 0.816 ± 0.219, 0.830 ± 0.685, 1.276 ± 1.151 and 1.606 ± 1.098, whereas the average levels of pATM were 59.359 ± 3.740, 63.366 ± 0.840, 66.273 ± 2.603 and 69.936 ± 4.439, in PBMCs exposed to 0, 1, 2 and 6 Gy, respectively. The linear-quadratic dose–response calibration curve for DCA was Y = 0.0017 (±0.0010) + 0.0251 (±0.0142) × D + 0.0342 (±0.0039) × D2 $\boldsymbol{Y}=\mathbf{0.0017}\left(\pm \mathbf{0.0010}\right)+\mathbf{0.0208}\left(\pm \mathbf{0.0218}\right)\times \boldsymbol{D}+\mathbf{0.0350}\left(\pm \mathbf{0.0050}\right)\times{\boldsymbol{D}}^{\mathbf{2}}$. Overall, despite a large variability in the ratio of γ-H2AX/total H2AX among donors, the present study revealed the suitability of using the ratio of γ-H2AX/total H2AX and pATM for biodosimetry. Still, more research with a larger group of subjects is necessary to construct a reliable calibration curve for the ratio of γ-H2AX/total H2AX and pATM levels for biodosimetry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HistonesRadiation ExposureHumansMalePilot ProjectsLymphocytesLeukocytes, MononuclearRadiometryEnzyme-Linked Immunosorbent AssayDose-Response Relationship, RadiationAtaxia Telangiectasia Mutated Proteins

Substanzen

HistonesATM protein, humanAtaxia Telangiectasia Mutated Proteins

Autor:innen und Institutionen

  • Research Center for Radioisotope, Radiopharmaceutical and Biodosimetry Technology, Research Organization for Nuclear Energy, National Research and Innovation Agency, Gedung 720 KST. BJ. Habibie, Jl. Raya Puspiptek 60, T…
  • Research Center for Safety, Metrology and Nuclear Quality Technology, Research Organization for Nuclear Energy, National Research and Innovation Agency, Gedung 720 KST. BJ. Habibie, Jl. Raya Puspiptek 60, Tangerang Sela…
  • Directorate of Strengthening and Partnership of Research and Innovation Infrastructure, Deputy for Research and Innovation Infrastructure, National Research and Innovation Agency, Jl. M.H.Thamrin No.8, Jakarta Pusat 103…
  • Department of Biology, Faculty of Science and Technology, Al-Azhar University of Indonesia, Komplek Masjid Agung Al Azhar Jl. Sisingamangaraja, Jakarta Selatan, Kebayoran Baru 12110, Indonesia.
  • Research Center for Radiation Process Technology, Research Organization for Nuclear Energy, National Research and Innovation Agency, Gedung 720 KST. BJ. Habibie, Jl. Raya Puspiptek 60, Tangerang Selatan, Banten 15310, I…
  • Institute of Radiation Emergency Medicine, Hirosaki University, Hirosaki, Aomori 036-8564, Japan.

ORCID-Profile: Dwi Ramadhani, Tomisato Miura

Förderung

  • Environmental Radioactivity Research Network Center

Zitieren

APA

Ramadhani, D., Tetriana, D., Purnami, S., Suvifan, V. A., Kurnia Hasan Basri, I., Kisnanto, T., Oktariyani, T. A., Syafira, D., Yunus, M. Y., Miura, T., Syaifudin, M., & Widowati, R. (2023). γ-H2AX and phospho-ATM enzyme-linked immunosorbent assays as biodosimetry methods for radiation exposure assessment: a pilot study. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad253

Vancouver

Ramadhani D, Tetriana D, Purnami S, Suvifan VA, Kurnia Hasan Basri I, Kisnanto T, et al. γ-H2AX and phospho-ATM enzyme-linked immunosorbent assays as biodosimetry methods for radiation exposure assessment: a pilot study. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad253

BibTeX
@article{Ramadhani2023,
  author = {Ramadhani, Dwi and Tetriana, Devita and Purnami, Sofiati and Suvifan, Viria Agesti and Kurnia Hasan Basri, Iin and Kisnanto, Teja and Oktariyani, Tiara Andalya and Syafira, Dira and Yunus, Muhamad Yasin and Miura, Tomisato and Syaifudin, Mukh and Widowati, Retno},
  title = {γ-H2AX and phospho-ATM enzyme-linked immunosorbent assays as biodosimetry methods for radiation exposure assessment: a pilot study},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncad253}
}
Kostenlos starten →