EUVIMEDEUVIMED entdecken
Crossref

EURADOS intercomparison IC2020ph on whole body dosemeters for photons

Argiro Boziari iD, Hannes Stadtmann iD, Panagiotis Askounis, Tom Grimbergen, Ana Romero iD, Andrew McWhan, Markus Figel

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncad201 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Argiro Boziari und 6 weiteren Autor:innen. Beteiligte Einrichtung: Dosimetry and Calibration Unit, Greek Atomic Energy Commission, Agia Paraskevi 15341, Greece. Hauptthemen laut MEDLINE: Radiation Monitoring, Radiation Protection, COVID-19, Occupational Exposure. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The European Dosimetry Group has been organising international intercomparisons (ICs) for personal dosemeters on a regular basis. The IC announced in 2020 was postponed to the end of 2020 and the beginning of 2021 due to coronavirus (COVID-19) restrictions. The irradiation plan consisted of nine irradiation setups with five different photon radiation qualities (S-Cs, S-Co, N-150, W-60, W-80) and two different angles of irradiation incidence (0o and 60o). A total of 112 monitoring services from 50 countries with 132 dosimetry systems participated. The present work describes and analyses the individual results for the personal dose equivalent quantities Hp(10) and, if submitted, Hp(0.07) for all participating systems. It also presents the organisational details and the difficulties arising from the COVID-19 crisis during the IC. The statistical results showed a satisfactory performance with the medians of all Hp(10) and Hp(0.07) response values very close to unity. However, there are few individual monitoring services with significant large variations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation MonitoringRadiation ProtectionCOVID-19Occupational ExposureHumansRadiation DosimetersRadiation DosageCalibrationPhotons

Autor:innen und Institutionen

  • Dosimetry and Calibration Unit, Greek Atomic Energy Commission, Agia Paraskevi 15341, Greece.
  • Seibersdorf Labor GmbH, Seibersdorf, Austria.
  • Mirion Dosimetry Services, JB Arnhem, The Netherlands.
  • CIEMAT, Radiation Dosimetry, Madrid, Spain.
  • Charthouse Data Management Ltd, Poole, United Kingdom.
  • Mirion Technologies (AWST) GmbH, Munich, Germany.

ORCID-Profile: Argiro Boziari, Hannes Stadtmann, Ana Romero

Zitieren

APA

Boziari, A., Stadtmann, H., Askounis, P., Grimbergen, T., Romero, A., McWhan, A., & Figel, M. (2023). EURADOS intercomparison IC2020ph on whole body dosemeters for photons. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad201

Vancouver

Boziari A, Stadtmann H, Askounis P, Grimbergen T, Romero A, McWhan A, et al. EURADOS intercomparison IC2020ph on whole body dosemeters for photons. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad201

BibTeX
@article{Boziari2023,
  author = {Boziari, Argiro and Stadtmann, Hannes and Askounis, Panagiotis and Grimbergen, Tom and Romero, Ana and McWhan, Andrew and Figel, Markus},
  title = {EURADOS intercomparison IC2020ph on whole body dosemeters for photons},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncad201}
}
Kostenlos starten →