EUVIMEDEUVIMED entdecken
Crossref

The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC)

Matteo Bolzonella, Marco Caresana, Philip J Gilvin, Eduardo G Yukihara, Marie-Anne Chevallier

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncad068 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Matteo Bolzonella und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Energy, Politecnico di Milano, Via Lambruschini 4, 20156 Milan, Italy. Hauptthemen laut MEDLINE: Radiation Protection, Radiation Monitoring, Occupational Exposure. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

CR-39 (PADC) nuclear track detectors are among the most widespread devices used for personal neutron dosimetry; however, some issues related to the variable material quality of the CR-39 polymer hinder the performance of CR-39-based dosemeters. For this reason, the Working Group 2 (WG2) of the European Radiation Dosimetry Group (EURADOS) has recently launched the CR-39 Quality task, a project aimed at improving and harmonising personal neutron dosimetry with CR-39 in Europe. Whitin this task, a close collaboration among researchers, individual monitoring services and dosemeter grade CR-39 manufacturers is achieved, thus facilitating the direct dialog between producer and consumer to reach an optimised material for personal neutron dosimetry applications.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation ProtectionRadiation MonitoringOccupational ExposureRadiation DosageRadiometryNeutronsPolyethylene Glycols

Substanzen

CR 39Polyethylene Glycols

Autor:innen und Institutionen

  • Department of Energy, Politecnico di Milano, Via Lambruschini 4, 20156 Milan, Italy.
  • Personal Dosimetry Service, UK Health Security Agency, Chilton, Didcot, Oxon OX11 0RQ, United Kingdom.
  • Department of Radiation Safety and Security, Paul Scherrer Institute, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland.
  • Dosimetry Research Department, Institut de Radioprotection et de Sûreté Nucléaire (IRSN), BP 17, 31 avenue de la Division Leclerc, 92260 Fontenay-aux-Roses, France.

Zitieren

APA

Bolzonella, M., Caresana, M., Gilvin, P. J., Yukihara, E. G., & Chevallier, M. A. (2023). The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC). Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad068

Vancouver

Bolzonella M, Caresana M, Gilvin PJ, Yukihara EG, Chevallier MA. The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC). Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad068

BibTeX
@article{Bolzonella2023,
  author = {Bolzonella, Matteo and Caresana, Marco and Gilvin, Philip J and Yukihara, Eduardo G and Chevallier, Marie-Anne},
  title = {The EURADOS CR-39 Quality task for the optimisation and harmonisation of personal neutron dosimetry with CR-39 (PADC)},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncad068}
}
Kostenlos starten →