EUVIMEDEUVIMED entdecken
Crossref

Assessment of the impact on a PADC neutron dosimetry system of the new operational dose quantities proposed in ICRU report 95

Brahim Moreno iD, Marc Million, David Thomas, Graeme Taylor

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncac212 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Brahim Moreno und 3 weiteren Autor:innen. Beteiligte Einrichtung: Landauer, 9, rue Paul Dautier - 78140, Vélizy-Villacoublay, France. Hauptthemen laut MEDLINE: Radiation Dosage, Radiation Monitoring, Radiometry, Occupational Exposure. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 7 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The International Commission on Radiation Units and Measurements, ICRU, have recommended, in ICRU Report 95, the adoption of new operational quantities for use in radiation protection monitoring. Their implementation will pose problems for instrument manufacturers supplying area dosemeters and for individual monitoring services providing personal dosemeters for radiation workers. The problems arise for photon, neutron and beta dosimetry, but this paper deals solely with neutron personal dosemeters based on poly-allyl diglycol carbonate (PADC) plastic. It presents information on the problems to be expected based on data from calibrations of actual personal neutron dosemeters in terms of the existing dose quantities.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageRadiation MonitoringRadiometryOccupational ExposureHumansNeutronsGlycols

Substanzen

diallyl glycol carbonateGlycols

Autor:innen und Institutionen

  • Landauer, 9, rue Paul Dautier - 78140, Vélizy-Villacoublay, France.
  • National Physical Laboratory, Hampton Road, Teddington, Middlesex TW11 0LW, UK.

ORCID-Profile: Brahim Moreno

Zitieren

APA

Moreno, B., Million, M., Thomas, D., & Taylor, G. (2023). Assessment of the impact on a PADC neutron dosimetry system of the new operational dose quantities proposed in ICRU report 95. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac212

Vancouver

Moreno B, Million M, Thomas D, Taylor G. Assessment of the impact on a PADC neutron dosimetry system of the new operational dose quantities proposed in ICRU report 95. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac212

BibTeX
@article{Moreno2023,
  author = {Moreno, Brahim and Million, Marc and Thomas, David and Taylor, Graeme},
  title = {Assessment of the impact on a PADC neutron dosimetry system of the new operational dose quantities proposed in ICRU report 95},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncac212}
}
Kostenlos starten →