RADIATION DOSE REDUCTION AT LOW TUBE VOLTAGE WITH CORONARY ARTERY BYPASS GRAFT COMPUTED TOMOGRAPHY ANGIOGRAPHY BASED ON THE CONTRAST NOISE RATIO INDEX
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncad049 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Takanori Masuda und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, …. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Drug Tapering. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
To compare the radiation dose and diagnostic ability of the 100-kVp protocol, based on the contrast noise ratio (CNR) index, during coronary artery bypass graft (CABG) vessels with those of the 120-kVp protocol. For the 120-kVp scans (150 patients), the targeted image level was set at 25 Hounsfield units (HU) (CNR120 = iodine contrast/25 HU). For the 100-kVp scans (150 patients), the targeted noise level was set at 30 HU to obtain the same CNR as in the 120-kVp scans (i.e. using 1.2-fold higher iodine contrast, CNR100 = 1.2 × iodine contrast/(1.2 × 25 HU) = CNR120). We compared the CNRs, radiation doses, detection of CABG vessels and visualisation scores of the scans acquired at 120 and 100 kVp, respectively. At the same CNR, the 100-kVp protocol may help reduce the radiation dose by ⁓30% compared with the 120-kVp protocol, without degradation of diagnostic ability during CABG.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan.
- Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, 1-1-1 Honjo, Kumamoto 860-8556, Japan.
- Department of Medical Physics, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
- Department of Diagnostic Radiology, Tsuchiya General Hospital, Nakajima-cho 3-30, Naka-ku, Hiroshima 730-8655, Japan.
- Department of Radiological Technology, Kawamura clinic Otemachi, Naka-ku, Hiroshima 730-0051, Japan.
- Department of Diagnostic Radiology, Graduate School of Biomedical Sciences, Hiroshima University, Hiroshima, Japan.
ORCID-Profile: Takanori Masuda, Takeshi Nakaura, Tomoyasu Sato
Zitieren
APA
Masuda, T., Nakaura, T., Funama, Y., Sato, T., Masuda, S., Gotanda, R., Arao, K., Imaizumi, H., Arao, S., Ono, A., Hiratsuka, J., & Awai, K. (2023). RADIATION DOSE REDUCTION AT LOW TUBE VOLTAGE WITH CORONARY ARTERY BYPASS GRAFT COMPUTED TOMOGRAPHY ANGIOGRAPHY BASED ON THE CONTRAST NOISE RATIO INDEX. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad049
Vancouver
Masuda T, Nakaura T, Funama Y, Sato T, Masuda S, Gotanda R, et al. RADIATION DOSE REDUCTION AT LOW TUBE VOLTAGE WITH CORONARY ARTERY BYPASS GRAFT COMPUTED TOMOGRAPHY ANGIOGRAPHY BASED ON THE CONTRAST NOISE RATIO INDEX. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad049
BibTeX
@article{Masuda2023,
author = {Masuda, Takanori and Nakaura, Takeshi and Funama, Yoshinori and Sato, Tomoyasu and Masuda, Shouko and Gotanda, Rumi and Arao, Keiko and Imaizumi, Hiromasa and Arao, Shinichi and Ono, Atsushi and Hiratsuka, Junichi and Awai, Kazuo},
title = {RADIATION DOSE REDUCTION AT LOW TUBE VOLTAGE WITH CORONARY ARTERY BYPASS GRAFT COMPUTED TOMOGRAPHY ANGIOGRAPHY BASED ON THE CONTRAST NOISE RATIO INDEX},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncad049}
}
EUVIMED