Kilovoltage X-ray beam quality effect on the relative response of alanine pellet dosemeters
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncad008 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Jakob G Hjørringgaard und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health Technology, Technical University of Denmark, Roskilde, Denmark. Hauptthemen laut MEDLINE: Alanine. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 15 Literaturangaben.
Abstract (Originalsprache)
Determination of beam quality correction factors is crucial for performing accurate alanine pellet dosimetry in non-reference fields. For some complex irradiation geometries, interpolation from literature data is more convenient than an experimental approach to establish these factors. Here we investigate the validity of extracting quality correction factors from literature data based on information on beam qualifiers such as half-value layer (HVL) or effective energy ${E}_{\text{eff}}$. A combination of Monte Carlo calculated dose ratios and a microdosimetric assessment of the relative efficiency allows for numerical evaluation of quality correction factors for a wide array of X-ray qualities. The computational analysis demonstrates that the average energy of the X-ray beam is optimal for characterizing the relative response. Special care should be taken when using the common X-ray beam qualifiers HVL or ${E}_{\text{eff}}$ to determine quality correction factors from literature data.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Health Technology, Technical University of Denmark, Roskilde, Denmark.
ORCID-Profile: Jakob G Hjørringgaard
Zitieren
APA
Hjørringgaard, J. G., Ankjærgaard, C., Miller, A., & Andersen, C. E. (2023). Kilovoltage X-ray beam quality effect on the relative response of alanine pellet dosemeters. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncad008
Vancouver
Hjørringgaard JG, Ankjærgaard C, Miller A, Andersen CE. Kilovoltage X-ray beam quality effect on the relative response of alanine pellet dosemeters. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncad008
BibTeX
@article{Hjrringgaard2023,
author = {Hjørringgaard, Jakob G and Ankjærgaard, Christina and Miller, Arne and Andersen, Claus E},
title = {Kilovoltage X-ray beam quality effect on the relative response of alanine pellet dosemeters},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncad008}
}
EUVIMED