COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncac277 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Ryo Moriwake und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Angiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
To compare the computed tomography (CT) number and the radiation dose between the 64 (group A) and 80-detector row (group B) during lower extremity computed tomography angiography (LE-CTA). We enrolled 144 patients underwent LE-CTA and compared the CT number for the popliteal arteries, radiation dose and the rate of the optimal CT number during the LE-CTA exceeding 200 HU between the two groups. The CT number for the popliteal arteries and mean dose-length product was significantly higher in Group A than in Group B (P < 0.01). The rate of the optimal CT number for the popliteal arteries was 23.6% with Group B scanner and 56.9% with Group A (P < 0.05). The 64-detector row CT was significantly higher in the CT number for the popliteal arteries, radiation dose and rate of the optimal CT number during the LE-CTA than the 80-detector row. Depiction ability did not improve by using a high CT scanner with a wider detector during LE-CTA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan.
- Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan.
- Department of Radiology, Kawasaki Medical School, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan.
ORCID-Profile: Takanori Masuda
Zitieren
APA
Moriwake, R., Masuda, T., Yamamoto, A., Ikenaga, H., Yoshida, K., Takei, Y., Yao, D., Ono, A., Hiratsuka, J., & Tamada, T. (2023). COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac277
Vancouver
Moriwake R, Masuda T, Yamamoto A, Ikenaga H, Yoshida K, Takei Y, et al. COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac277
BibTeX
@article{Moriwake2023,
author = {Moriwake, Ryo and Masuda, Takanori and Yamamoto, Akira and Ikenaga, Hiroyuki and Yoshida, Koji and Takei, Yasutaka and Yao, Daiki and Ono, Atsushi and Hiratsuka, Junichi and Tamada, Tsutomu},
title = {COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncac277}
}
EUVIMED