COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY

Ryo Moriwake, Takanori Masuda iD, Akira Yamamoto, Hiroyuki Ikenaga, Koji Yoshida, Yasutaka Takei, Daiki Yao, Atsushi Ono, Junichi Hiratsuka, Tsutomu Tamada

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncac277 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Ryo Moriwake und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Angiography. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To compare the computed tomography (CT) number and the radiation dose between the 64 (group A) and 80-detector row (group B) during lower extremity computed tomography angiography (LE-CTA). We enrolled 144 patients underwent LE-CTA and compared the CT number for the popliteal arteries, radiation dose and the rate of the optimal CT number during the LE-CTA exceeding 200 HU between the two groups. The CT number for the popliteal arteries and mean dose-length product was significantly higher in Group A than in Group B (P < 0.01). The rate of the optimal CT number for the popliteal arteries was 23.6% with Group B scanner and 56.9% with Group A (P < 0.05). The 64-detector row CT was significantly higher in the CT number for the popliteal arteries, radiation dose and rate of the optimal CT number during the LE-CTA than the 80-detector row. Depiction ability did not improve by using a high CT scanner with a wider detector during LE-CTA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Computed Tomography AngiographyAngiographyHumansTomography, X-Ray ComputedLower ExtremityRadiation Dosage

Autor:innen und Institutionen

  • Department of Radiological Technology, Kawasaki Medical School Hospital, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan.
  • Department of Radiological Technology, Faculty of Health Science and Technology, Kawasaki University of Medical Welfare, 288, Matsushima, Kurashiki, Okayama 701-0193, Japan.
  • Department of Radiology, Kawasaki Medical School, 577, Matsushima, Kurashiki, Okayama 701-0192, Japan.

ORCID-Profile: Takanori Masuda

Zitieren

APA

Moriwake, R., Masuda, T., Yamamoto, A., Ikenaga, H., Yoshida, K., Takei, Y., Yao, D., Ono, A., Hiratsuka, J., & Tamada, T. (2023). COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac277

Vancouver

Moriwake R, Masuda T, Yamamoto A, Ikenaga H, Yoshida K, Takei Y, et al. COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac277

BibTeX
@article{Moriwake2023,
  author = {Moriwake, Ryo and Masuda, Takanori and Yamamoto, Akira and Ikenaga, Hiroyuki and Yoshida, Koji and Takei, Yasutaka and Yao, Daiki and Ono, Atsushi and Hiratsuka, Junichi and Tamada, Tsutomu},
  title = {COMPARISON OF THE 64- AND 80-DETECTOR ROW COMPUTED TOMOGRAPHY AMONG THE CT NUMBER AND RADIATION DOSE DURING LOWER EXTREMITY COMPUTED TOMOGRAPHY ANGIOGRAPHY},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncac277}
}
Kostenlos starten →