EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

High-pitch CT pulmonary angiography (CTPA) with ultra-low contrast medium volume for the detection of pulmonary embolism: a comparison with standard CTPA

Tobias Schönfeld, Patrick Seitz, Christian Krieghoff, Slavica Ponorac, Alexander Wötzel, Stefan Olthoff, Sebastian Schaudt, Jonas Steglich, Matthias Gutberlet, Robin F Gohmann

European Radiology · 2023

DOI: 10.1007/s00330-023-10101-8 ↗

Kurz gefasst

Fachartikel in der Zeitschrift European Radiology, 2023. Verfasst von Tobias Schönfeld und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany. Hauptthemen laut MEDLINE: Hypertension, Pulmonary, Pulmonary Embolism. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 38 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Universität Leipzig.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To investigate the feasibility and image quality of high-pitch CT pulmonary angiography (CTPA) with reduced iodine volume in normal weight patients.

Methods

In total, 81 normal weight patients undergoing CTPA for suspected pulmonary arterial embolism were retrospectively included: 41 in high-pitch mode with 20 mL of contrast medium (CM); and 40 with normal pitch and 50 mL of CM. Subjective image quality was assessed and rated on a 3-point scale. For objective image quality, attenuation and noise values were measured in all pulmonary arteries from the trunk to segmental level. Contrast-to-noise ratio (CNR) was calculated. Radiation dose estimations were recorded.

Results

There were no statistically significant differences in patient and scan demographics between high-pitch and standard CTPA. Subjective image quality was rated good to excellent in over 90% of all exams with no significant group differences ( p = 0.32). Median contrast opacification was lower in high-pitch CTPA (283.18 [216.06–368.67] HU, 386.81 [320.57–526.12] HU; p = 0.0001). CNR reached a minimum of eight in all segmented arteries, but was lower in high-pitch CTPA (8.79 [5.82–12.42], 11.01 [9.19–17.90]; p = 0.005). Median effective dose of high-pitch CTPA was lower (1.04 [0.72–1.27] mSv/mGy·cm; 1.49 [1.07–2.05] mSv/mGy·cm; p < 0.0001).

Conclusion

High-pitch CTPA using ultra-low contrast volume (20 mL) rendered diagnostic images for the detection of pulmonary arterial embolism in most instances. Compared to standard CTPA, the high-pitch CTPA exams with drastically reduced contrast medium volume had also concomitantly reduced radiation exposure. However, objective image quality of high-pitch CTPA was worse, though likely still within acceptable limits for confident diagnosis. Clinical relevance This study provides valuable insights on the performance of a high-pitch dual-source CTPA protocol, offering potential benefits in reducing contrast medium and radiation dose while maintaining sufficient image quality for accurate diagnosis in patients suspected of pulmonary embolism. Key Points • High-pitch CT pulmonary angiography (CTPA) with ultra-low volume of contrast medium and reduced radiation dose renders diagnostic examinations with comparable subjective image quality to standard CTPA in most patients. • Objective image quality of high-pitch CTPA is reduced compared to standard CTPA, but contrast opacification and contrast-to-noise ratio remain above diagnostic thresholds. • Challenges of high-pitch CTPA may potentially be encountered in patients with severe heart failure or when performing a Valsalva maneuver during the examination.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hypertension, PulmonaryPulmonary EmbolismHumansRetrospective StudiesPulmonary ArteryTomography, X-Ray ComputedAngiographyRadiation DosageComputed Tomography AngiographyContrast Media

Stichwörter der Autor:innen

Computed tomography pulmonary angiographyDual-source pulmonary angiographyHigh-pitch modeMotion artifactsPulmonary embolism

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
  • Department of General and Geriatric Medicine, St. Elisabeth-Hospital Leipzig, Biedermannstr. 84, 04277, Leipzig, Germany.
  • Medical Faculty, University of Leipzig, Liebigstr. 27, 04103, Leipzig, Germany.
  • Institute of Radiology, University Medical Centre Ljubljana, Zaloška Cesta 7, 1000, Ljubljana, Slovenia.
  • Emergency Department, Helios Park-Clinic Leipzig, Strümpellstr. 41, 04289, Leipzig, Germany.
  • Leipzig Heart Institute, Russenstr. 69a, 04289, Leipzig, Germany.

Förderung

  • Universität Leipzig

Zitieren

APA

Schönfeld, T., Seitz, P., Krieghoff, C., Ponorac, S., Wötzel, A., Olthoff, S., Schaudt, S., Steglich, J., Gutberlet, M., & Gohmann, R. F. (2023). High-pitch CT pulmonary angiography (CTPA) with ultra-low contrast medium volume for the detection of pulmonary embolism: a comparison with standard CTPA. European Radiology. https://doi.org/10.1007/s00330-023-10101-8

Vancouver

Schönfeld T, Seitz P, Krieghoff C, Ponorac S, Wötzel A, Olthoff S, et al. High-pitch CT pulmonary angiography (CTPA) with ultra-low contrast medium volume for the detection of pulmonary embolism: a comparison with standard CTPA. European Radiology. 2023. doi:10.1007/s00330-023-10101-8

BibTeX
@article{Schnfeld2023,
  author = {Schönfeld, Tobias and Seitz, Patrick and Krieghoff, Christian and Ponorac, Slavica and Wötzel, Alexander and Olthoff, Stefan and Schaudt, Sebastian and Steglich, Jonas and Gutberlet, Matthias and Gohmann, Robin F},
  title = {High-pitch CT pulmonary angiography (CTPA) with ultra-low contrast medium volume for the detection of pulmonary embolism: a comparison with standard CTPA},
  journal = {European Radiology},
  year = {2023},
  doi = {10.1007/s00330-023-10101-8}
}
Kostenlos starten →