Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Sandra Barna und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Medical University of Vienna, Vienna 1090, Austria. Hauptthemen laut MEDLINE: Protons, Proton Therapy. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 10 Literaturangaben. Gefördert von: Austrian Science Fund FWF, Austrian Science Fund.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The aim of this work is to present the first microdosimetric spectra measured with a miniaturised tissue-equivalent proportional counter in the clinical environment of the MedAustron ion-beam therapy facility. These spectra were gathered with a 62.4-MeV proton beam and have been compared with microdosimetric spectra measured in the 62-MeV clinical proton beam of the CATANA beam line. Monte Carlo simulations were performed using the Geant4 toolkit GATE and a fully commissioned clinical beam line model. Finally, similarities and discrepancies of the measured data to simulations based on a simple and complex detector geometry are discussed.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ProtonsProton TherapyRadiometryRadiotherapy DosageMonte Carlo Method

Substanzen

Protons

Autor:innen und Institutionen

  • Department of Radiation Oncology, Medical University of Vienna, Vienna 1090, Austria.
  • Radiation Physics, Technische Universität Wien, Vienna 1040, Austria.
  • MedAustron Ion Therapy Center, Wiener Neustadt 2700, Austria.
  • Laboratori Nazionali di Legnaro, Istituto Nazionale di Fisica Nucleare, Legnaro 20133, Italy.
  • National Physical Laboratory, Teddington TW11 0LW, UK.

ORCID-Profile: Sandra Barna, Anna Bianchi, Anna Selva

Förderung

  • Austrian Science Fund FWF
  • Austrian Science Fund

Zitieren

APA

Barna, S., Meouchi, C., Magrin, G., Bianchi, A., Conte, V., Selva, A., Stock, M., Resch, A. F., Georg, D., & Palmans, H. (2023). First microdosimetric measurements with a tissue-equivalent proportional counter at the MedAustron ion-beam therapy facility. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac252

Vancouver

Barna S, Meouchi C, Magrin G, Bianchi A, Conte V, Selva A, et al. First microdosimetric measurements with a tissue-equivalent proportional counter at the MedAustron ion-beam therapy facility. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac252

BibTeX
@article{Barna2023,
  author = {Barna, Sandra and Meouchi, Cynthia and Magrin, Giulio and Bianchi, Anna and Conte, Valeria and Selva, Anna and Stock, Markus and Resch, Andreas Franz and Georg, Dietmar and Palmans, Hugo},
  title = {First microdosimetric measurements with a tissue-equivalent proportional counter at the MedAustron ion-beam therapy facility},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncac252}
}
Kostenlos starten →