EYE RADIATION DOSE SAVING IN HEAD CT EXAMINATIONS USING COPPER-BISMUTH RADIATION SHIELD
Radiation Protection Dosimetry · 2023
DOI: 10.1093/rpd/ncac249 ↗Kurz gefasst
Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Mohammad Keshtkar und 3 weiteren Autor:innen. Beteiligte Einrichtung: Medical Physics and Radiology Department, Faculty of Medicine, Infectious Diseases Research Center, Gonabad University of Medical Sciences, Sento roa…. Hauptthemen laut MEDLINE: Bismuth, Radiation Protection. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 25 Literaturangaben.
Abstract (Originalsprache)
The aim of the present study is to fabricate a new shield with an optimal combination of copper and bismuth to protect the eyes in the head computed tomography (CT) examinations without compromising image quality. Radiation shields with different compositions were constructed. Computed Tomography Dose Index phantom was used to evaluate the effectiveness of shields in dose reduction and their impact on image quality quantitatively. The shield that caused the least noise in the phantom study was selected for human study. The 10%Bi-90%Cu shield had the least effect on increasing the image noise, and also no remarkable artifact was seen in the CT image of the phantom. The patient study showed that only in 25% of the study group the artifact was observed so that it did not distort the interpretation of the image. It can be concluded that the 10%Bi-90%Cu shield is flexible and durable and would be safely used in the clinic to reduce the eye radiation dose in head CT imaging without compromising image quality.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Medical Physics and Radiology Department, Faculty of Medicine, Infectious Diseases Research Center, Gonabad University of Medical Sciences, Sento road, Gonabad, Iran.
- Student of General Medicine, Faculty of Medicine, Gonabad University of Medical Sciences, Sento road, Gonabad, Iran.
- Department of Epidemiology and Biostatistics, School of Public Health; Social Determinants of Health Research Center, Gonabad University of Medical Sciences, Sento road, Gonabad, Iran.
ORCID-Profile: Mohammad Keshtkar
Zitieren
APA
Keshtkar, M., Blouri, B., Mahmoudabadi, A., & Alami, A. (2023). EYE RADIATION DOSE SAVING IN HEAD CT EXAMINATIONS USING COPPER-BISMUTH RADIATION SHIELD. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac249
Vancouver
Keshtkar M, Blouri B, Mahmoudabadi A, Alami A. EYE RADIATION DOSE SAVING IN HEAD CT EXAMINATIONS USING COPPER-BISMUTH RADIATION SHIELD. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac249
BibTeX
@article{Keshtkar2023,
author = {Keshtkar, Mohammad and Blouri, Basir and Mahmoudabadi, Alireza and Alami, Ali},
title = {EYE RADIATION DOSE SAVING IN HEAD CT EXAMINATIONS USING COPPER-BISMUTH RADIATION SHIELD},
journal = {Radiation Protection Dosimetry},
year = {2023},
doi = {10.1093/rpd/ncac249}
}
EUVIMED