EUVIMEDEUVIMED entdecken
Crossref

The effect of fitting the reference photon dose–response on the clonogenic survival predicted with the Mayo Clinic Florida microdosimetric kinetic model in case of accelerated ions

Alessio Parisi iD, Chris J Beltran, Keith M Furutani

Radiation Protection Dosimetry · 2023

DOI: 10.1093/rpd/ncac235 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiation Protection Dosimetry, 2023. Verfasst von Alessio Parisi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, United States of America. Hauptthemen laut MEDLINE: Photons. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 10 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The Mayo Clinic Florida microdosimetric kinetic model (MCF MKM) is a recently developed clonogenic survival model. Since the MCF MKM relies on novel strategies to a priori determine the cell-specific model parameters, the only experiment-specific input values are the α and ß terms of the linear–quadratic model (LQM) of clonogenic survival for the reference photon exposure. Because the two LQM terms are anti-correlated, the fitting process of the reference photon survival curve was found to significantly influence the MCF MKM calculations. This article reports this effect for two clinically relevant cell lines (human brain glioblastoma A-172, human healthy foreskin fibroblasts AG01522) and ions (1H and 12C ions).

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PhotonsHumansFloridaCell LineIonsLinear ModelsRelative Biological EffectivenessCell Survival

Substanzen

Ions

Autor:innen und Institutionen

  • Department of Radiation Oncology, Mayo Clinic, Jacksonville, Florida, United States of America.

ORCID-Profile: Alessio Parisi

Zitieren

APA

Parisi, A., Beltran, C. J., & Furutani, K. M. (2023). The effect of fitting the reference photon dose–response on the clonogenic survival predicted with the Mayo Clinic Florida microdosimetric kinetic model in case of accelerated ions. Radiation Protection Dosimetry. https://doi.org/10.1093/rpd/ncac235

Vancouver

Parisi A, Beltran CJ, Furutani KM. The effect of fitting the reference photon dose–response on the clonogenic survival predicted with the Mayo Clinic Florida microdosimetric kinetic model in case of accelerated ions. Radiation Protection Dosimetry. 2023. doi:10.1093/rpd/ncac235

BibTeX
@article{Parisi2023,
  author = {Parisi, Alessio and Beltran, Chris J and Furutani, Keith M},
  title = {The effect of fitting the reference photon dose–response on the clonogenic survival predicted with the Mayo Clinic Florida microdosimetric kinetic model in case of accelerated ions},
  journal = {Radiation Protection Dosimetry},
  year = {2023},
  doi = {10.1093/rpd/ncac235}
}
Kostenlos starten →