EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Improved prostate diffusion imaging using deep learning denoising and phase correction with ultra-high-density coil array

Sherry S Huang iD, Xinzeng Wang iD, Patricia Lan iD, Milica Medved iD, Nurullah Kaya, Clyve K Follante, Yunjeong Stickle, Jonathan Taylor, Ambereen Yousuf, Roger Engelmann, Fraser J L Robb, Arnaud Guidon und 2 weitere

Radiology Advances · 03.03.2026 · 3 (2)

DOI: 10.1093/radadv/umag019 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology Advances, online erschienen am 28.03.2026. Verfasst von Sherry S Huang und 13 weiteren Autor:innen. Beteiligte Einrichtung: Research and Scientific Affairs, GE HealthCare, Rochester, MN, 55901, United States. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: GE HealthCare.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

MR diffusion-weighted imaging (DWI), especially at high b-value, is a key acquisition to help identify clinically significant prostate cancer; however, it suffers from low signal-to-noise ratio (SNR), high noise floor, and susceptibility artifact.

Purpose

To demonstrate the feasibility of improving DWI quality using a novel 50-channel pelvic coil in conjunction with a deep learning (DL)-based phase correction and a DL-denoising algorithm.

Methods

In this prospective, single-center study, 24 consecutive men referred for prostate multiparametric MRI over 16 months were enrolled (age 47–79 years; mean, 68.1 years). Axial T2-weighted images and DWI were obtained using a prototype 50‑channel coil and standard clinical phased array (3 T Architect, GE HealthCare, USA). The DWI acquisitions were reconstructed with the vendor’s deep learning denoising algorithm (ARDL). The same raw data were reconstructed offline using an investigational DL Phase Correction algorithm with ARDL (DLPC+ARDL). Two independent readers scored DWI and ADC series using 4 qualitative criteria. SNR and contrast-to-noise ratio (CNR) were measured on b = 1500 s/mm2 images. Combined reader scores were compared using the Wilcoxon matched‑pairs signed‑rank test, inter‑reader variability was assessed using Cohen’s κ, and quantitative SNR/CNR values were compared using 2‑tailed paired t‑tests.

Results

Twenty men were analyzable for qualitative and 18 for quantitative metrics (reported as mean ± SD). 50‑channel pelvic coil with DLPC+ARDL produced the highest SNR (99.70 ± 28.50) and CNR (91.68 ± 44.39), exceeding 50‑channel with ARDL alone (SNR 56.44 ± 28.50; CNR 51.11 ± 28.67), 30‑channel anterior array with ARDL (SNR 31.41 ± 13.18; CNR 26.26 ± 13.52), and DLPC + ARDL (SNR 49.4 ± 18.6; CNR 44.7 ± 18.3) (all P < .0001). Reader scores favored DLPC+ARDL in prostate border definition, peripheral/transition zone distinction, lesion conspicuity, and confidence of extraprostatic extension (all P values for DWI at b = 1500 s/mm2 < 0.0001; synthetic DWI at b = 2000 s/mm2: P = 7.5 × 10−7–0.01). Inter‑reader agreement was fair for acquired DWI (quadratic‑weighted κ = 0.34) and lower for synthetic DWI (κ = 0.19).

Conclusion

DWI images acquired using the 50‑channel pelvic coil and reconstructed with the DLPC + ARDL pipeline yield the highest image quality compared to ARDL only pipeline and to all 30-channel coil imaging.

Schlagwörter

Stichwörter der Autor:innen

deep-learning denoisingdeep-learning reconstructiondiffusion weighted imagingflexible-coil-arrayphase correctionprostate MRI

Autor:innen und Institutionen

  • Research and Scientific Affairs, GE HealthCare, Rochester, MN, 55901, United States.
  • MR Clinical Solutions & Research Collaborations, GE HealthCare, Houston, TX, 77030, United States.
  • MR Clinical Solutions & Research Collaborations, GE HealthCare, Menlo Park, CA, 94025, United States.
  • Department of Radiology, University of Chicago, Chicago, IL, 60637, United States.
  • MR Coils, GE HealthCare, Aurora, OH, 44202, United States.
  • MR Clinical Solutions & Research Collaborations, GE HealthCare, Aurora, OH, 44202, United States.

ORCID-Profile: Sherry S Huang, Xinzeng Wang, Patricia Lan, Milica Medved, Grace Lee

Förderung

  • GE HealthCare

Zitieren

APA

Huang, S. S., Wang, X., Lan, P., Medved, M., Kaya, N., Follante, C. K., Stickle, Y., Taylor, J., Yousuf, A., Engelmann, R., Robb, F. J. L., Guidon, A., Lee, G., & Oto, A. (2026). Improved prostate diffusion imaging using deep learning denoising and phase correction with ultra-high-density coil array. Radiology Advances, 3(2). https://doi.org/10.1093/radadv/umag019

Vancouver

Huang SS, Wang X, Lan P, Medved M, Kaya N, Follante CK, et al. Improved prostate diffusion imaging using deep learning denoising and phase correction with ultra-high-density coil array. Radiology Advances. 2026;3(2). doi:10.1093/radadv/umag019

BibTeX
@article{Huang2026,
  author = {Huang, Sherry S and Wang, Xinzeng and Lan, Patricia and Medved, Milica and Kaya, Nurullah and Follante, Clyve K and Stickle, Yunjeong and Taylor, Jonathan and Yousuf, Ambereen and Engelmann, Roger and Robb, Fraser J L and Guidon, Arnaud and Lee, Grace and Oto, Aytekin},
  title = {Improved prostate diffusion imaging using deep learning denoising and phase correction with ultra-high-density coil array},
  journal = {Radiology Advances},
  year = {2026},
  volume = {3},
  number = {2},
  doi = {10.1093/radadv/umag019}
}
Kostenlos starten →