Application of the wireless wearable monitoring system improves the turnaround time in gastrointestinal endoscopy center
Postgraduate Medical Journal · 17.08.2025 · 101 (1199) · 873-879
DOI: 10.1093/postmj/qgaf103 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift Postgraduate Medical Journal, online erschienen am 30.06.2025. Verfasst von Bo Zhu und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, Chengdu Second People's Hospital, No. 10, South Qingyun Street, Jinjiang District, Chengdu 610095, China. Hauptthemen laut MEDLINE: Wireless Technology, Endoscopy, Gastrointestinal, Wearable Electronic Devices. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 17 Literaturangaben. Gefördert von: Chengdu Municipal Health Commission.
Abstract (Originalsprache)
Objectives
To investigate whether the wireless monitoring system can reduce the turnaround time in gastrointestinal endoscopy center.
Methods
Enrolled patients were randomly allocated to the study or control group. The primary outcome was the turnaround time. The secondary outcomes included the total time from entering examination room to discharge (T1), the total time of monitoring mean arterial pressure (T5), incidences of hypotension, bradycardia, and hypoxia, evaluation of the medical staff, and rate of effective monitoring.
Results
166 patients were analyzed. The turnaround time of study group was significantly shorter than that of control group (1.49 ± 1.82 vs. 4.78 ± 3.77 min, P < .001). The study group had a significantly shorter T1 (44.69 ± 4.54 vs. 49.49 ± 5.53 min, P < .001), but a longer T5 (44.39 ± 4.38 vs. 42.21 ± 4.97 min, P = .012). The medical staff gave higher scores to the wireless monitoring system in terms of practicability and application value (P < .05), but gave equally high evaluations on data reliability (P > .05). The rate of effective monitoring was acceptable in both groups.
Conclusion
Application of the wireless monitoring system in an endoscopy center is feasible and acceptable, and improves the turnaround time.
Trial registration
This study was registered at the Chinese Clinical Trial Registry on 19 April 2024 (ChiCTR2400083277).
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology, Chengdu Second People's Hospital, No. 10, South Qingyun Street, Jinjiang District, Chengdu 610095, China.
- Department of Gastroenterology, Chengdu Second People's Hospital, No. 10, South Qingyun Street, Jinjiang District, Chengdu 610095, China.
Förderung
- Chengdu Municipal Health Commission
Zitieren
APA
Zhu, B., Huang, Y., Liu, Y., Wang, M., & Liu, L. (2025). Application of the wireless wearable monitoring system improves the turnaround time in gastrointestinal endoscopy center. Postgraduate Medical Journal, 101(1199), 873-879. https://doi.org/10.1093/postmj/qgaf103
Vancouver
Zhu B, Huang Y, Liu Y, Wang M, Liu L. Application of the wireless wearable monitoring system improves the turnaround time in gastrointestinal endoscopy center. Postgraduate Medical Journal. 2025;101(1199):873-879. doi:10.1093/postmj/qgaf103
BibTeX
@article{Zhu2025,
author = {Zhu, Bo and Huang, Yu and Liu, Yi and Wang, Min and Liu, Ling},
title = {Application of the wireless wearable monitoring system improves the turnaround time in gastrointestinal endoscopy center},
journal = {Postgraduate Medical Journal},
year = {2025},
volume = {101},
number = {1199},
pages = {873--879},
doi = {10.1093/postmj/qgaf103}
}
EUVIMED