Y-switch: a spring-loaded synthetic gene switch for robust DNA/RNA signal amplification and detection
Nucleic Acids Research · 23.09.2024 · 52 (17) · e80-e80
DOI: 10.1093/nar/gkae680 ↗Kurz gefasst
Fachartikel in der Zeitschrift Nucleic Acids Research, online erschienen am 16.08.2024. Verfasst von Krishna Gupta und 1 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Biofunctional Polymer Materials, Leibniz Institute of Polymer Research Dresden, Dresden, Germany. Hauptthemen laut MEDLINE: SARS-CoV-2, Zika Virus, COVID-19. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 73 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: BMBF, NanoMatFutur.
Abstract (Originalsprache)
Nucleic acid tests (NATs) are essential for biomedical diagnostics. Traditional NATs, often complex and expensive, have prompted the exploration of toehold-mediated strand displacement (TMSD) circuits as an economical alternative. However, the wide application of TMSD-based reactions is limited by ‘leakage’—the spurious activation of the reaction leading to high background signals and false positives. Here, we introduce the Y-Switch, a new TMSD cascade design that recognizes a custom nucleic acid input and generates an amplified output. The Y-Switch is based on a pair of thermodynamically spring-loaded DNA modules. The binding of a predefined nucleic acid target triggers an intermolecular reaction that activates a T7 promoter, leading to the perpetual transcription of a fluorescent aptamer that can be detected by a smartphone camera. The system is designed to permit the selective depletion of leakage byproducts to achieve high sensitivity and zero-background signal in the absence of the correct trigger. Using Zika virus (ZIKV)- and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-derived nucleic acid sequences, we show that the assay generates a reliable target-specific readout. Y-Switches detect native RNA under isothermal conditions without reverse transcription or pre-amplification, with a detection threshold as low as ∼200 attomole. The modularity of the assay allows easy re-programming for the detection of other targets by exchanging a single sequence domain. This work provides a low-complexity and high-fidelity synthetic biology tool for point-of-care diagnostics and for the construction of more complex biomolecular computations.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Institute for Biofunctional Polymer Materials, Leibniz Institute of Polymer Research Dresden, Dresden, Germany.
- Faculty of Chemistry and Food Chemistry, TU Dresden, Dresden, Germany.
ORCID-Profile: Krishna Gupta, Elisha Krieg
Förderung
- BMBF
- NanoMatFutur
Zitieren
APA
Gupta, K., & Krieg, E. (2024). Y-switch: a spring-loaded synthetic gene switch for robust DNA/RNA signal amplification and detection. Nucleic Acids Research, 52(17), e80-e80. https://doi.org/10.1093/nar/gkae680
Vancouver
Gupta K, Krieg E. Y-switch: a spring-loaded synthetic gene switch for robust DNA/RNA signal amplification and detection. Nucleic Acids Research. 2024;52(17):e80-e80. doi:10.1093/nar/gkae680
BibTeX
@article{Gupta2024,
author = {Gupta, Krishna and Krieg, Elisha},
title = {Y-switch: a spring-loaded synthetic gene switch for robust DNA/RNA signal amplification and detection},
journal = {Nucleic Acids Research},
year = {2024},
volume = {52},
number = {17},
pages = {e80--e80},
doi = {10.1093/nar/gkae680}
}
EUVIMED