Movement Quality Assessment of Army Reserve Officers’ Training Corps Cadets: A Report of Validity and Normative Data
Military Medicine · 2024
DOI: 10.1093/milmed/usae266 ↗Kurz gefasst
Fachartikel in der Zeitschrift Military Medicine, 2024. Verfasst von Erin Lally und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Health and Human Performance, Jowers Center, Texas State University, San Marcos, TX 78666, USA. Hauptthemen laut MEDLINE: Military Personnel. Die Arbeit nennt 40 Literaturangaben.
Abstract (Originalsprache)
Introduction
Movement quality screening in early-career military populations, like Army Reserve Officers’ Training Corps (AROTC) cadets, could decrease the negative impact of musculoskeletal injury observed within the military. Movement quality screening techniques should be valid before being pursued in the field. Normative data describing movement quality of AROTC cadets are also needed. Therefore, the aims of this study were to determine criterion validity of several movement quality assessments and report normative jump-landing kinematics of AROTC cadets. Materials and Methods This cross-sectional research was approved by the Institutional Review Board. As part of a larger study, 20 AROTC cadets (21.3 ± 3.4 years; 1.7 ± 0.1 m; 73.8 ± 14.8 kg) had 3-dimensional (3D) and 2-dimensional (2D) kinematic data collected simultaneously while performing a jump-landing task. Variables of interest were 3D hip and knee sagittal, frontal, and transverse joint angles at maximum knee flexion. An experienced rater calculated sagittal and frontal 2D joint angles at maximum knee flexion. Averages of 2D and 3D angles were calculated to describe normative data and for further data analysis. Bivariate correlations between 3D and 2D variables were used to determine criterion validity.
Results
Moderate correlations were found between 2D and 3D hip frontal plane angles (P = .05, r =−0.33), 2D and 3D knee sagittal plane angles (P = .04, r = 0.35), and 2D and 3D knee frontal plane angles (P = .03, r = −0.36). Normative values of knee and hip kinematics demonstrated averages of 17.58° of knee adduction, 16.48° of knee external rotation, 11.57° of hip abduction, 10.76° of hip internal rotation, and 103.47° of knee flexion during landings. However, ranges demonstrated that landing patterns vary within AROTC cadets.
Conclusions
The normative values of 3D jump-landing kinematic data indicate that movement quality varies greatly within AROTC cadets, and some cadets display potentially injurious movements. Therefore, screening movement quality could be beneficial to determine musculoskeletal injury risk in AROTC cadets. Based on the correlations discovered in this study, we recommend the 2D techniques used in this study be researched further as they may serve as alternatives to expensive, timely 3D techniques that could be better utilized in military environments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Health and Human Performance, Jowers Center, Texas State University, San Marcos, TX 78666, USA.
- Department of Kinesiology, McCormick Hall, Illinois State University, Normal, IL 61761, USA.
- Department of Kinesiology, Klotsche Center, University of Wisconsin-Milwaukee, Milwaukee, WI 53211, USA.
ORCID-Profile: Erin Lally
Zitieren
APA
Lally, E., Ericksen, H., Mach, M., & Earl-Boehm, J. (2024). Movement Quality Assessment of Army Reserve Officers’ Training Corps Cadets: A Report of Validity and Normative Data. Military Medicine. https://doi.org/10.1093/milmed/usae266
Vancouver
Lally E, Ericksen H, Mach M, Earl-Boehm J. Movement Quality Assessment of Army Reserve Officers’ Training Corps Cadets: A Report of Validity and Normative Data. Military Medicine. 2024. doi:10.1093/milmed/usae266
BibTeX
@article{Lally2024,
author = {Lally, Erin and Ericksen, Hayley and Mach, Madison and Earl-Boehm, Jennifer},
title = {Movement Quality Assessment of Army Reserve Officers’ Training Corps Cadets: A Report of Validity and Normative Data},
journal = {Military Medicine},
year = {2024},
doi = {10.1093/milmed/usae266}
}
EUVIMED