Validation of Markerless Motion Capture for Soldier Movement Patterns Assessment Under Varying Body-Borne Loads
Annals of Biomedical Engineering · 2025
DOI: 10.1007/s10439-024-03622-w ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Annals of Biomedical Engineering, 2025. Verfasst von Isabel Coll und 4 weiteren Autor:innen. Beteiligte Einrichtung: Ottawa-Carleton Institute of Biomedical Engineering (OCIBME), Faculty of Engineering, University of Ottawa, 75 Laurier Ave. E, Ottawa, ON, K1N 6N5, C…. Hauptthemen laut MEDLINE: Military Personnel, Muscle, Skeletal, Weight-Bearing, Walking. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: Fonds Québécois de la Recherche sur la Nature et les Technologies, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Field performance of modern soldiers is affected by an increase in body-borne load due to technological advancements related to their armour and equipment. In this project, the Theia3D markerless motion capture system was compared to the marker-based gold standard for capturing movement patterns of participants wearing various body-borne loads. The aim was to estimate lower body joint kinematics, gastrocnemius lateralis and medialis muscle activation patterns, and lower body joint reaction forces from the two motion capture systems. Data were collected on 16 participants performing three repetitions of walking and running under four body-borne load conditions by both motion capture systems simultaneously. A complete musculoskeletal analysis was completed in OpenSim. Strong correlations ( r > 0.8 ) and acceptable differences were observed between the kinematics of the marker-based and markerless systems. Timing of muscle activations of the gastrocnemius lateralis and medialis, as estimated through OpenSim from both systems, agreed with the ones measured using electromyography. Joint reaction force results showed a very strong correlation ( r > 0.9 ) between the systems; however, the markerless model estimated greater joint reaction forces when compared the marker-based model due to differences in muscle recruitment strategy. Overall, this research highlights the potential of markerless motion capture to track participants wearing body-borne loads.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Ottawa-Carleton Institute of Biomedical Engineering (OCIBME), Faculty of Engineering, University of Ottawa, 75 Laurier Ave. E, Ottawa, ON, K1N 6N5, Canada. icoll077@uottawa.ca.
- School of Human Kinetics, University of Ottawa, 75 Laurier Ave. E, Ottawa, ON, K1N 6N5, Canada.
- Defence Research and Development Canada - Toronto Research Centre, 1133 Sheppard Ave. W, Toronto, ON, M3K 2C9, Canada.
- Ottawa-Carleton Institute of Biomedical Engineering (OCIBME), Faculty of Engineering, University of Ottawa, 75 Laurier Ave. E, Ottawa, ON, K1N 6N5, Canada.
Förderung
- Fonds Québécois de la Recherche sur la Nature et les Technologies
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Coll, I., Mavor, M. P., Karakolis, T., Graham, R. B., & Clouthier, A. L. (2025). Validation of Markerless Motion Capture for Soldier Movement Patterns Assessment Under Varying Body-Borne Loads. Annals of Biomedical Engineering. https://doi.org/10.1007/s10439-024-03622-w
Vancouver
Coll I, Mavor MP, Karakolis T, Graham RB, Clouthier AL. Validation of Markerless Motion Capture for Soldier Movement Patterns Assessment Under Varying Body-Borne Loads. Annals of Biomedical Engineering. 2025. doi:10.1007/s10439-024-03622-w
BibTeX
@article{Coll2025,
author = {Coll, Isabel and Mavor, Matthew P and Karakolis, Thomas and Graham, Ryan B and Clouthier, Allison L},
title = {Validation of Markerless Motion Capture for Soldier Movement Patterns Assessment Under Varying Body-Borne Loads},
journal = {Annals of Biomedical Engineering},
year = {2025},
doi = {10.1007/s10439-024-03622-w}
}
EUVIMED