EUVIMEDEUVIMED entdecken
Crossref

Cryo-EM with a Laser Phase Plate

Jessie T Zhang

Microscopy and Microanalysis · 27.07.2026 · 32 (Supplement_1)

DOI: 10.1093/mam/ozag053.449 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 27.07.2026. Verfasst von Jessie T Zhang.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cryo-EM imaging of vitrified biological specimens is a powerful technique to observe cellular systems in vitro and in situ, but is fundamentally limited by weak phase contrast of the specimens and electron radiation damage. In conventional cryo-EM, a defocus is applied to generate contrast, resulting in a contrast transfer function (CTF) that has a weak signal at low spatial frequencies and oscillations at high frequencies, which can limit particle detection, alignment, and interpretability under low-dose conditions. In this talk, I will discuss the development of a laser phase plate (LPP) at UC Berkeley. A phase plate can increase the contrast in the low frequency components of the image by imparting a 90o phase shift to the unscattered electron beam in the back focal plane of the microscope. While there have been many attempts to implement a phase plate for electron microscopy, most involve a material object in the electron beam path, leading to charging and signal loss. We have previously developed a phase plate based on a high-intensity laser cavity which circumvents these issues and demonstrated the use in cryo-EM in a prototype system. We recently built and integrated a new laser phase plate into a state-of-the-art Krios equipped with a custom transfer-optics module and improved optics design. This opens exciting new possibilities with the LPP, which we are now beginning to explore in full capacity. I will present recent results on single particle analysis (SPA) of small proteins using the LPP, where we observe a significant improvement in final resolution with the LPP, and ongoing work in spherical aberration-corrected in-focus imaging with the LPP, which promises near unity contrast transfer function at all spatial frequencies limited primarily by the electron coherence envelope. I will also discuss the application of the LPP in cryo-ET, and provide an outlook for the application of the laser phase plate in more complex and biologically relevant samples.

Zitieren

APA

Zhang, J. T. (2026). Cryo-EM with a Laser Phase Plate. Microscopy and Microanalysis, 32(Supplement_1). https://doi.org/10.1093/mam/ozag053.449

Vancouver

Zhang JT. Cryo-EM with a Laser Phase Plate. Microscopy and Microanalysis. 2026;32(Supplement_1). doi:10.1093/mam/ozag053.449

BibTeX
@article{Zhang2026,
  author = {Zhang, Jessie T},
  title = {Cryo-EM with a Laser Phase Plate},
  journal = {Microscopy and Microanalysis},
  year = {2026},
  volume = {32},
  number = {Supplement_1},
  doi = {10.1093/mam/ozag053.449}
}
Kostenlos starten →