Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography
IUCrJ · 01.05.2026 · 13 (3) · 260-272
DOI: 10.1107/s2052252526002575 ↗Kurz gefasst
Fachartikel in der Zeitschrift IUCrJ, online erschienen am 09.04.2026. Verfasst von Joshua Hutchings und 18 weiteren Autor:innen. Beteiligte Einrichtung: BioHub, Redwood City, California, USA. Hauptthemen laut MEDLINE: Cryoelectron Microscopy, Electron Microscope Tomography, Image Processing, Computer-Assisted. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The Volta phase plate (VPP) can enhance low-frequency phase contrast in cryo-electron microscopy (cryo-EM) and cryo-electron tomography (cryo-ET), but its impact on tomogram alignment has not been systematically assessed. Using sub-2 Å single-particle analysis (SPA) and analytical contrast transfer function (CTF) modeling, we show that despite high-frequency information loss and moderate signal damping, the VPP enhances signal in low-frequency bands that are crucial for tilt-series alignment. We show that VPP tomograms exhibit increased contrast and remain higher in contrast post denoising, for thick and crowded specimens. Quantitative comparison of tomograms acquired with and without the VPP shows improved tilt-axis orientation measurements and a higher fraction of tomograms amenable to local tilt-series alignment. Although acquisition with the VPP yields lower subtomogram averaging (STA) resolution, these results show that the primary benefits of the VPP for cryo-ET are contrast enhancement and improved tilt-series alignment robustness, which are crucial for studying cellular ultrastructure and protein organization in crowded environments, where STA at moderate resolutions remains valuable.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- BioHub, Redwood City, California, USA.
ORCID-Profile: Daniel Ji, Utz H Ermel, Mohammadreza Paraan, Norbert S Hill
Zitieren
APA
Hutchings, J., Ji, D., Zheng, S., Montabana, E. A., Ermel, U. H., Peck, A., Schwartz, J., Woldeyes, R., Paraan, M., Ali, M., Hill, N. S., Siems, H., Serwas, D., Cheng, A., Kimanius, D., Agard, D. A., Potter, C. S., Carragher, B., & Yu, Y. (2026). Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography. IUCrJ, 13(3), 260-272. https://doi.org/10.1107/s2052252526002575
Vancouver
Hutchings J, Ji D, Zheng S, Montabana EA, Ermel UH, Peck A, et al. Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography. IUCrJ. 2026;13(3):260-272. doi:10.1107/s2052252526002575
BibTeX
@article{Hutchings2026,
author = {Hutchings, Joshua and Ji, Daniel and Zheng, Shawn and Montabana, Elizabeth A and Ermel, Utz H and Peck, Ariana and Schwartz, Jonathan and Woldeyes, Rahel and Paraan, Mohammadreza and Ali, Mallak and Hill, Norbert S and Siems, Hannah and Serwas, Daniel and Cheng, Anchi and Kimanius, Dari and Agard, David A and Potter, Clinton S and Carragher, Bridget and Yu, Yue},
title = {Evaluating the Volta phase plate for improved tomogram alignment in cryo-electron tomography},
journal = {IUCrJ},
year = {2026},
volume = {13},
number = {3},
pages = {260--272},
doi = {10.1107/s2052252526002575}
}
EUVIMED