Multislice Ptychography on an Uncorrected Electron Microscope
Microscopy and Microanalysis · 27.07.2026 · 32 (Supplement_1)
DOI: 10.1093/mam/ozag053.225 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 27.07.2026. Verfasst von Anna Li und 2 weiteren Autor:innen. Die Arbeit nennt 10 Literaturangaben.
Abstract (Originalsprache)
The development of hardware-based aberration-correction has now allowed for sub-angstrom resolution imaging in transmission electron microscopes (TEMs) and scanning transmission electron microscopes (STEMs) for several decades [1]. However, the high cost of acquiring, operating, and maintaining aberration-corrected microscopes continues to limit access to sub-angstrom electron microscopy. Ptychography in uncorrected STEMs offers an alternative to hardware-based aberration correctors. Electron ptychography is a phase-retrieval approach that utilizes four-dimensional (4D)-STEM data to solve for an image from a series of convergent-beam electron diffraction (CBED) patterns [2,3]. By separately solving for the probe and object, ptychography computationally corrects aberrations. Recently, sub-0.5-angstrom resolution has been demonstrated in twisted 2D materials in uncorrected STEMs using single-slice electron ptychography [4]. These results, and other efforts to develop electron ptychography in uncorrected STEM [5,6], indicate the potential for electron ptychography to provide a new, lower-cost route to sub-angstrom resolution. However, because of the strong interactions between electrons and matter, single-slice ptychography is limited to samples thinner than ~5 nm, precluding its use for most TEM specimens. Here, we demonstrate multislice electron ptychography on a commercially available uncorrected STEM. Multislice electron ptychography (MEP) allows for the retrieval of the 3D structure of a sample by dividing the sample into a series of slices [7,8]. We test the performance of MEP over a range of materials systems for an uncorrected STEM. After optimizing our acquisition and processing methods to minimize the effects of experimental challenges such as drift and sample contamination, we find that we can achieve sub-angstrom in-plane resolution and few-nm depth resolution in an uncorrected electron microscope. Figure 1 shows the performance of MEP on twisted bilayer WSe2. As shown in Fig. 1(b-c), we obtained an in-plane resolution of 0.48Å, as measured from the information transfer of the fast Fourier transform (FFT). By examining the depth slices for the twisted bilayer WSe2 reconstruction, we show that we can distinguish the top and bottom WSe2 layers. Using the z-profiles of individual W atoms (Fig. 1(d-e)), we estimate a depth resolution of 1.8 nm, comparable to the previously reported 2–4 nm depth resolutions [7] of experimental MEP of standard TEM specimens using aberration-corrected STEMs but poorer than the highest depth resolution obtained for 2D materials in aberration-corrected STEM [9]. Across a range of samples, including metallic nanoparticles and SrTiO3, we attain a lateral resolution below 1 Å (Fig. 2(d)), indicating the broad potential applicability of MEP for sub-angstrom resolution electron ptychography in uncorrected STEMs [10]. Multislice ptychography of twisted bilayer WSe2. a) Structure of WSe2 with 3.79° twist angle. W is in gray and Se is in green. b) 2D projection of multislice ptychographic reconstruction of WSe2. c) FFT of the object phase showing an information transfer limit of 0.48 Å. d) Cross section of the region marked in yellow in (b). e) Histogram of the full-width half-maxima of W atom intensities along the z-direction. f and h) Depth slices from ptychographic reconstructions with the top WSe2 layer dominating the intensity in (f) and the bottom layer in (h). g and i) Line profiles of intensity taken from regions shown in f and h respectively. Atoms in the top WSe2 layer appear brighter in f-g, and atoms in the bottom WSe2 layer appear brighter in h-i, allowing us to distinguish the two WSe2 layers. Scale bar = 2 nm. Multislice ptychographic reconstruction of SrTiO3. a) Annular dark field STEM (ADF-STEM) image of 5 nm-thick SrTiO3 along the [001] zone axis. b) 2D projection of a multislice ptychographic reconstruction of SrTiO3. c) FFT of ADF-STEM image in (a) showing an information transfer limit of 1.76 Å. d) Diffractogram of the 2D projection of the phase image in (b) showing an information transfer limit of 0.87 Å. Scale bars = 1 nm.
Zitieren
APA
Li, A., Huang, J., & Huang, P. (2026). Multislice Ptychography on an Uncorrected Electron Microscope. Microscopy and Microanalysis, 32(Supplement_1). https://doi.org/10.1093/mam/ozag053.225
Vancouver
Li A, Huang J, Huang P. Multislice Ptychography on an Uncorrected Electron Microscope. Microscopy and Microanalysis. 2026;32(Supplement_1). doi:10.1093/mam/ozag053.225
BibTeX
@article{Li2026,
author = {Li, Anna and Huang, Jeffrey and Huang, Pinshane},
title = {Multislice Ptychography on an Uncorrected Electron Microscope},
journal = {Microscopy and Microanalysis},
year = {2026},
volume = {32},
number = {Supplement_1},
doi = {10.1093/mam/ozag053.225}
}
EUVIMED