EUVIMEDEUVIMED entdecken
Crossref

Achieving sub-0.5-angstrom–resolution ptychography in an uncorrected electron microscope

Kayla X Nguyen iD, Yi Jiang iD, Chia-Hao Lee iD, Priti Kharel iD, Yue Zhang iD, Arend M van der Zande iD, Pinshane Y Huang iD

Science · 23.02.2024 · 383 (6685) · 865-870

DOI: 10.1126/science.adl2029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Science, erschienen am 23.02.2024. Verfasst von Kayla X Nguyen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA. Die Arbeit wurde bisher 76-mal zitiert (Crossref) und nennt 73 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Subangstrom resolution has long been limited to aberration-corrected electron microscopy, where it is a powerful tool for understanding the atomic structure and properties of matter. Here, we demonstrate electron ptychography in an uncorrected scanning transmission electron microscope (STEM) with deep subangstrom spatial resolution down to 0.44 angstroms, exceeding the conventional resolution of aberration-corrected tools and rivaling their highest ptychographic resolutions​. Our approach, which we demonstrate on twisted two-dimensional materials in a widely available commercial microscope, far surpasses prior ptychographic resolutions (1 to 5 angstroms) of uncorrected STEMs. We further show how geometric aberrations can create optimized, structured beams for dose-efficient electron ptychography. Our results demonstrate that expensive aberration correctors are no longer required for deep subangstrom resolution.

Autor:innen und Institutionen

  • Department of Materials Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA.
  • Advanced Photon Source Facility, Argonne National Laboratory, Lemont, IL, USA.
  • Department of Chemistry, University of Illinois Urbana-Champaign, Urbana, IL, USA.
  • Department of Mechanical Science and Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA.
  • Materials Research Laboratory, University of Illinois Urbana-Champaign, Urbana, IL, USA.

ORCID-Profile: Kayla X Nguyen, Yi Jiang, Chia-Hao Lee, Priti Kharel, Yue Zhang, Arend M van der Zande, Pinshane Y Huang

Zitieren

APA

Nguyen, K. X., Jiang, Y., Lee, C. H., Kharel, P., Zhang, Y., van der Zande, A. M., & Huang, P. Y. (2024). Achieving sub-0.5-angstrom–resolution ptychography in an uncorrected electron microscope. Science, 383(6685), 865-870. https://doi.org/10.1126/science.adl2029

Vancouver

Nguyen KX, Jiang Y, Lee CH, Kharel P, Zhang Y, van der Zande AM, et al. Achieving sub-0.5-angstrom–resolution ptychography in an uncorrected electron microscope. Science. 2024;383(6685):865-870. doi:10.1126/science.adl2029

BibTeX
@article{Nguyen2024,
  author = {Nguyen, Kayla X and Jiang, Yi and Lee, Chia-Hao and Kharel, Priti and Zhang, Yue and van der Zande, Arend M and Huang, Pinshane Y},
  title = {Achieving sub-0.5-angstrom–resolution ptychography in an uncorrected electron microscope},
  journal = {Science},
  year = {2024},
  volume = {383},
  number = {6685},
  pages = {865--870},
  doi = {10.1126/science.adl2029}
}
Kostenlos starten →