Integration of a Broad Argon Ion Beam Into a Scanning Electron Microscope for In-Situ Large-Area Surface Preparation and Analysis
Microscopy and Microanalysis · 01.07.2026 · 32 (4)
DOI: 10.1093/mam/ozag046 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 02.07.2026. Verfasst von Chen Jia und 8 weiteren Autor:innen. Beteiligte Einrichtung: School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, Hefei, Anhui 230026,…. Die Arbeit nennt 29 Literaturangaben. Gefördert von: and Development Program of China, Innovation and Entrepreneurship Leading Talent Program of Suzhou.
Abstract (Originalsprache)
In-situ, large-area, and high-quality surface preparation is essential for statistically representative microstructure characterization. Focused ion beam (FIB) systems are typically confined to scales below a hundred microns, while standalone broad ion beam (BIB) polishing systems often suffer from surface contamination and repositioning errors during sample transfer. Herein, we report an integrated argon broad ion beam scanning electron microscope (BIB-SEM) system achieved by mounting an electron cyclotron resonance (ECR) ion source directly into the SEM chamber. Three key engineering challenges were addressed through dual-layer magnetic shielding to suppress stray fields from the ECR ion source, a sputter-shielding assembly to mitigate debris contamination, and a wide-range tilt stage enabling flexible polishing angles and EBSD analysis. The integration establishes an iterative polishing-and-characterization workflow, allowing for in-situ assessment and parameter optimization without breaking vacuum. This capability enabled feedback-driven optimization on aluminum alloy to reach 99.98% EBSD indexing rates, uniform surfaces on molybdenum with >98% EBSD indexing rates across multiple regions on a ∼21 mm2 area, statistical analysis of estimated over 8 × 105 NCM811 particle cross-sections, and rapid cleaning of contaminated surface within 5 min. This integrated BIB-SEM system enables in-situ, millimeter-scale surface preparation with SEM/EBSD validation, advancing representative microstructural characterization in materials science.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Biomedical Engineering (Suzhou), Division of Life Science and Medicine, University of Science and Technology of China, Hefei, Anhui 230026, China.
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, Jiangsu 215163, China.
- Yidon Technologies Co., Ltd., Suzhou, Jiangsu 215163, China.
ORCID-Profile: Chen Jia
Förderung
- and Development Program of China
- Innovation and Entrepreneurship Leading Talent Program of Suzhou
Zitieren
APA
Jia, C., Lu, Y., Deng, J., Wei, S., Shen, Z., Yu, L., Gu, G., Wei, D., & Tang, Y. (2026). Integration of a Broad Argon Ion Beam Into a Scanning Electron Microscope for In-Situ Large-Area Surface Preparation and Analysis. Microscopy and Microanalysis, 32(4). https://doi.org/10.1093/mam/ozag046
Vancouver
Jia C, Lu Y, Deng J, Wei S, Shen Z, Yu L, et al. Integration of a Broad Argon Ion Beam Into a Scanning Electron Microscope for In-Situ Large-Area Surface Preparation and Analysis. Microscopy and Microanalysis. 2026;32(4). doi:10.1093/mam/ozag046
BibTeX
@article{Jia2026,
author = {Jia, Chen and Lu, Yan and Deng, Jiangwei and Wei, Shaoqing and Shen, Zheling and Yu, Lei and Gu, Guogang and Wei, Dongguang and Tang, Yuguo},
title = {Integration of a Broad Argon Ion Beam Into a Scanning Electron Microscope for In-Situ Large-Area Surface Preparation and Analysis},
journal = {Microscopy and Microanalysis},
year = {2026},
volume = {32},
number = {4},
doi = {10.1093/mam/ozag046}
}
EUVIMED