Optimizing Contrast in Automated 4D STEM Cryotomography
Microscopy and Microanalysis · 04.07.2024 · 30 (3) · 476-488
DOI: 10.1093/mam/ozae050 ↗Kurz gefasst
Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 17.06.2024. Verfasst von Shahar Seifer und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biological Physics, Weizmann Institute of Science, 234 Herzl St, Rehovot 7610001, Israel. Die Arbeit wurde bisher 19-mal zitiert (Crossref) und nennt 50 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: European Union.
Abstract (Originalsprache)
4D STEM is an emerging approach to electron microscopy. While it was developed principally for high-resolution studies in materials science, the possibility to collect the entire transmitted flux makes it attractive for cryomicroscopy in application to life science and radiation-sensitive materials where dose efficiency is of utmost importance. We present a workflow to acquire tomographic tilt series of 4D STEM data sets using a segmented diode and an ultrafast pixelated detector, demonstrating the methods using a specimen of a T4 bacteriophage. Full integration with the SerialEM platform conveniently provides all the tools for grid navigation and automation of the data collection. Scripts are provided to convert the raw data to mrc format files and further to generate a variety of modes representing both scattering and phase contrasts, including incoherent and annular bright field, integrated center of mass, and parallax decomposition of a simulated integrated differential phase contrast. Principal component analysis of virtual annular detectors proves particularly useful, and axial contrast is improved by 3D deconvolution with an optimized point spread function. Contrast optimization enables visualization of irregular features such as DNA strands and thin filaments of the phage tails, which would be lost upon averaging or imposition of an inappropriate symmetry.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Chemical and Biological Physics, Weizmann Institute of Science, 234 Herzl St, Rehovot 7610001, Israel.
ORCID-Profile: Shahar Seifer, Peter Kirchweger, Karlina Maria Edel, Michael Elbaum
Förderung
- European Union
Zitieren
APA
Seifer, S., Kirchweger, P., Edel, K. M., & Elbaum, M. (2024). Optimizing Contrast in Automated 4D STEM Cryotomography. Microscopy and Microanalysis, 30(3), 476-488. https://doi.org/10.1093/mam/ozae050
Vancouver
Seifer S, Kirchweger P, Edel KM, Elbaum M. Optimizing Contrast in Automated 4D STEM Cryotomography. Microscopy and Microanalysis. 2024;30(3):476-488. doi:10.1093/mam/ozae050
BibTeX
@article{Seifer2024,
author = {Seifer, Shahar and Kirchweger, Peter and Edel, Karlina Maria and Elbaum, Michael},
title = {Optimizing Contrast in Automated 4D STEM Cryotomography},
journal = {Microscopy and Microanalysis},
year = {2024},
volume = {30},
number = {3},
pages = {476--488},
doi = {10.1093/mam/ozae050}
}
EUVIMED