Shadow Montage and Cone-Beam Reconstruction in 4D-STEM Tomography

Shahar Seifer iD, Lothar Houben iD, Michael Elbaum iD

Microscopy and Microanalysis · 02.01.2026 · 32 (1)

DOI: 10.1093/mam/ozaf126 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Microscopy and Microanalysis, online erschienen am 14.01.2026. Verfasst von Shahar Seifer und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot 76100, Israel. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Diffraction images in a scanning transmission electron microscope (STEM) provide a real-space projection of the sample at sufficient probe defocus. Such shadow images may be acquired patch by patch in a 4D-STEM setup using a pixelated detector and assembled into a shadow montage. Consequently, an upscaled bright-field image is rendered efficiently in time compared to other STEM techniques. We show that this procedure achieves the result of a tilt-corrected bright-field image. Furthermore, the solution is equivalent to cone-beam reconstruction in a particular scenario of a scanning point illumination source in a plane. Contrast transfer is similar to that of conventional TEM, but like STEM, the focus is insensitive to energy loss and objective lens chromatic aberration. By adjusting the overlap between shadow patch images, the shadow montage is derived from or synchronized to specific layers in the sample, similarly to multi-slice ptychography, rendering a 3D shadow volume from a single dataset. The method is amenable to conventional tilt tomography by summing shadow volumes of all tilt views to generate a full back-projection reconstruction. This approach effectively circumvents the basic presumption of parallel-projection tomography that the depth of field must be greater than the specimen thickness.

Schlagwörter

Stichwörter der Autor:innen

4D STEMcone-beam reconstructioncryoEMmultislicetomography

Autor:innen und Institutionen

  • Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot 76100, Israel.
  • Chemical Research Support Department, Weizmann Institute of Science, Rehovot 76100, Israel.

ORCID-Profile: Shahar Seifer, Lothar Houben, Michael Elbaum

Zitieren

APA

Seifer, S., Houben, L., & Elbaum, M. (2026). Shadow Montage and Cone-Beam Reconstruction in 4D-STEM Tomography. Microscopy and Microanalysis, 32(1). https://doi.org/10.1093/mam/ozaf126

Vancouver

Seifer S, Houben L, Elbaum M. Shadow Montage and Cone-Beam Reconstruction in 4D-STEM Tomography. Microscopy and Microanalysis. 2026;32(1). doi:10.1093/mam/ozaf126

BibTeX
@article{Seifer2026,
  author = {Seifer, Shahar and Houben, Lothar and Elbaum, Michael},
  title = {Shadow Montage and Cone-Beam Reconstruction in 4D-STEM Tomography},
  journal = {Microscopy and Microanalysis},
  year = {2026},
  volume = {32},
  number = {1},
  doi = {10.1093/mam/ozaf126}
}
Kostenlos starten →