Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis
Laboratory Medicine · 05.10.2026 · 57 (6)
DOI: 10.1093/labmed/lmag086 ↗Kurz gefasst
Systematische Übersicht in der Zeitschrift Laboratory Medicine, online erschienen am 04.11.2026. Verfasst von Young-Hee Lee und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Nursing, Dongnam Health University, Suwon, Republic of Korea. Hauptthemen laut MEDLINE: Hemolysis, Blood Specimen Collection, Specimen Handling. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Dongnam Health University.
Abstract (Originalsprache)
Introduction
Hemolysis and other preanalytical errors compromise laboratory test accuracy, delay reporting, and may require repeat specimen collection.
Methods
We conducted a PROSPERO-registered systematic review and meta-analysis following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 statement. PubMed/MEDLINE and KoreaMed were searched from inception to May 17, 2026, with supplementary manual and institutional source searching. Eligible studies evaluated preanalytical interventions related to blood specimen collection or handling and reported hemolysis, specimen rejection, recollection, misidentification, or broader preanalytical error outcomes. Risk ratios for hemolysis were pooled using a random-effects model; secondary outcomes were summarized narratively.
Results
Seventeen studies were included in the qualitative synthesis, and 7 provided event and denominator data for hemolysis meta-analysis. Preanalytical interventions reduced hemolysis compared with conventional practice (risk ratio, 0.48 [95% CI, 0.28-0.81]; P = .0066), representing an approximately 52% relative risk reduction. Heterogeneity was substantial (I2 = 92.4%). Secondary studies generally reported reductions in sample rejection, nonconforming specimens, or broader preanalytical errors. Certainty of evidence was low for hemolysis and very low for secondary outcomes.
Discussion
Preanalytical quality interventions may reduce hemolysis and improve specimen quality, but evidence remains limited by heterogeneity, nonrandomized designs, and inconsistent outcome reporting.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Nursing, Dongnam Health University, Suwon, Republic of Korea.
- Department of Biomedical Laboratory Science, College of Health Sciences, Sangji University, Wonju, Republic of Korea.
- Department of Integrated Medical Humanities, Graduate School, Kyung Hee University, Seoul, Republic of Korea.
- Department of Clinical Laboratory Science, Dongnam Health University, Suwon, Republic of Korea.
ORCID-Profile: Young-Hee Lee, Ho-Keun Choi, Kyung A Jung, Hyun Ho Sung
Förderung
- Dongnam Health University
Zitieren
APA
Lee, Y. H., Choi, H. K., Jung, K. A., & Sung, H. H. (2026). Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis. Laboratory Medicine, 57(6). https://doi.org/10.1093/labmed/lmag086
Vancouver
Lee YH, Choi HK, Jung KA, Sung HH. Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis. Laboratory Medicine. 2026;57(6). doi:10.1093/labmed/lmag086
BibTeX
@article{Lee2026,
author = {Lee, Young-Hee and Choi, Ho-Keun and Jung, Kyung A and Sung, Hyun Ho},
title = {Preanalytical interventions to reduce hemolysis and improve specimen quality: a systematic review and meta-analysis},
journal = {Laboratory Medicine},
year = {2026},
volume = {57},
number = {6},
doi = {10.1093/labmed/lmag086}
}
EUVIMED