Fachartikel in der Zeitschrift Laboratory Medicine, 2025. Verfasst von Anna C Bitzer und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, US. Hauptthemen laut MEDLINE: Trace Elements, Polypropylenes. Die Arbeit nennt 30 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Due to the ability of metal ions to cross the blood–brain barrier, there has been interest in analyzing cerebrospinal fluid (CSF) for trace element concentrations to investigate possible correlations with neurodegenerative diseases. In this study, Sarstedt polypropylene CSF collection tubes were analyzed to determine the contamination levels of aluminum, titanium, chromium, manganese, cobalt, nickel, molybdenum, gadolinium, vanadium, arsenic, cadmium, mercury, lead, thallium, selenium, copper, zinc, and iron.

Methods

Sarstedt polypropylene CSF collection tubes from 2 separate lots (n = 10 per lot) were filled with a 2 mL aliquot of a CSF pool with known element concentrations. After 24 hours of leaching at room temperature, all 18 elements were analyzed via inductively coupled plasma mass spectrometry (ICP-MS). Results were subtracted from the initial pool concentration to determine contamination levels.

Results

No detectable contamination above the assay limit of detection was found in 11 analytes. Molybdenum and selenium contamination was measured in all tubes, and aluminum, titanium, manganese, thallium, and zinc had minimal levels of sporadic detectable contamination in 25% or fewer of the tubes tested.

Conclusions

Sarstedt polypropylene CSF tubes are an acceptable collection tube for the analysis of most assessed metals in CSF.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Trace ElementsPolypropylenesHumansMetalsSpecimen HandlingCerebrospinal FluidMass Spectrometry

Stichwörter der Autor:innen

CSFSarstedtcerebrospinal fluidconcentrationscontaminationpolypropylenetubes

Substanzen

Trace ElementsPolypropylenesMetals

Autor:innen und Institutionen

  • Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, US.

Zitieren

APA

Bitzer, A. C., Jannetto, P. J., & Bornhorst, J. A. (2025). Evaluation of polypropylene CSF low-bind collection tubes for trace metal contamination. Laboratory Medicine. https://doi.org/10.1093/labmed/lmae067

Vancouver

Bitzer AC, Jannetto PJ, Bornhorst JA. Evaluation of polypropylene CSF low-bind collection tubes for trace metal contamination. Laboratory Medicine. 2025. doi:10.1093/labmed/lmae067

BibTeX
@article{Bitzer2025,
  author = {Bitzer, Anna C and Jannetto, Paul J and Bornhorst, Joshua A},
  title = {Evaluation of polypropylene CSF low-bind collection tubes for trace metal contamination},
  journal = {Laboratory Medicine},
  year = {2025},
  doi = {10.1093/labmed/lmae067}
}
Kostenlos starten →