Direct multi-elemental analysis of cerebrospinal fluid samples by LA-ICP-MS employing an aerosol local extraction cryogenic ablation cell
Analytical and Bioanalytical Chemistry · 2023
DOI: 10.1007/s00216-023-04878-2 ↗Kurz gefasst
Fachartikel in der Zeitschrift Analytical and Bioanalytical Chemistry, 2023. Verfasst von Fan Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, 430074, People's Repu…. Hauptthemen laut MEDLINE: Mass Spectrometry, Trace Elements, Cerebrospinal Fluid. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 39 Literaturangaben. Gefördert von: the National Key R&D Program of China, National Natural Science Foundation of China.
Abstract (Originalsprache)
A novel method for direct high-throughput analysis of multi-elements in cerebrospinal fluid (CSF) samples by laser ablation inductively coupled plasma mass spectrometry with an aerosol local extraction cryogenic ablation cell (ALEC-LA-ICP-MS) was developed. Microliter-level CSF samples were frozen by a designed cryogenic ablation cell and directly analyzed by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) without time-consuming pretreatment. Compared with the precision obtained at room temperature (20℃), that obtained at low temperature (- 25℃) was significantly improved; the RSDs were reduced from 8.3% (Zn) to 32.6% (Mn) to 2.2% (Pb) to 6.5% (Mn) with six times parallel determination. To meet the analytical requirement of the micro-volume CSF samples, the laminar flow aerosol local extraction strategy was adopted to improve the transmission efficiency of aerosols, and the signal intensity was increased by four times compared with the standard commercial ablation cell. The standard solution with 0.4% bovine serum albumin (BSA) matrix was used as matrix-match external standard, and Rh was added into the samples as internal standard. The limits of detection (LODs) ranged from 0.17 μg·L-1 (Mn) to 8.67 μg·L-1 (Mg). Standard addition recovery experiments and the determination of CRM serum L-1 and L-2 were carried out to validate the accuracy of the method; all results indicated there were excellent accuracy and precision in the proposed method. The matrix-scanning function in the GeoLas software combined with the microwell plate realizes the high-throughput automatic analysis. Twenty-four CSF samples from different patients were determined; the results showed that there might be a correlation between the metal elements in CSF and the diseases, which means that the proposed method has potential in the diagnosis of neurological diseases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, 430074, People's Republic of China.
- Department of Clinical Laboratory, Renmin Hospital of Wuhan University, Wuhan, 430060, People's Republic of China.
- State Key Laboratory of Biogeology and Environmental Geology, School of Earth Sciences, China University of Geosciences, Wuhan, 430074, People's Republic of China. shhu@cug.edu.cn.
Förderung
- the National Key R&D Program of China
- National Natural Science Foundation of China
Zitieren
APA
Li, F., Cui, H., Zhang, D., Li, H., Guo, W., Jin, L., & Hu, S. (2023). Direct multi-elemental analysis of cerebrospinal fluid samples by LA-ICP-MS employing an aerosol local extraction cryogenic ablation cell. Analytical and Bioanalytical Chemistry. https://doi.org/10.1007/s00216-023-04878-2
Vancouver
Li F, Cui H, Zhang D, Li H, Guo W, Jin L, et al. Direct multi-elemental analysis of cerebrospinal fluid samples by LA-ICP-MS employing an aerosol local extraction cryogenic ablation cell. Analytical and Bioanalytical Chemistry. 2023. doi:10.1007/s00216-023-04878-2
BibTeX
@article{Li2023,
author = {Li, Fan and Cui, Hua and Zhang, Dingwen and Li, Huilai and Guo, Wei and Jin, Lanlan and Hu, Shenghong},
title = {Direct multi-elemental analysis of cerebrospinal fluid samples by LA-ICP-MS employing an aerosol local extraction cryogenic ablation cell},
journal = {Analytical and Bioanalytical Chemistry},
year = {2023},
doi = {10.1007/s00216-023-04878-2}
}
EUVIMED