EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Repeatability and reliability of left ventricular focused cardiac ultrasound parameters in dogs obtained and measured by two non-cardiologist clinicians

Christopher R Kennedy, Aurelie Jordan, Kris Gommeren, Anne-Christine Merveille

Journal of Veterinary Internal Medicine · 2026

DOI: 10.1093/jvimsj/aalaf090 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Internal Medicine, 2026. Verfasst von Christopher R Kennedy und 3 weiteren Autor:innen. Beteiligte Einrichtung: Département clinique des animaux de compagnie, Université de Liège, Liège, Belgium. Hauptthemen laut MEDLINE: Heart Ventricles, Echocardiography. Die Arbeit nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Focused cardiac ultrasound (FCU) of the left ventricle (LV) is performed by non-cardiologists in critical care settings. Validity of measurements relies on accurate acquisition and measurement techniques. Hypothesis/Objectives Investigate the acquisition and measurement repeatability of selected LV parameters and report reliability compared with measurements made by a board-certified cardiologist, with the goal of identifying parameters that might warrant further investigation in FCU. Animals Thirty hemodynamically stable dogs with sinus cardiac rhythms.

Methods

Right-sided FCU was performed by 2 critical care clinicians and a cardiologist. Left ventricular (LV) diameters, fractional shortening, and E-point septal separation (EPSS) were recorded. Intra-operator acquisition repeatability was quantified by coefficients of variation (CVacquisition); inter-operator reliability (compared with the cardiologist) was described by intraclass correlation coefficients (ICCinter-operator) and CVinter-operator; intra-operator measurement repeatability was described by ICCmeasurement.

Results

Left ventricular end-diastolic diameter (LVEDD) in short-axis B-mode had excellent repeatability and reliability for both critical care clinicians (CVacquisition < 10%; CVinter-operator < 10%, ICCinter-operator > 0.9; ICCmeasurement > 0.9). Left ventricular end-diastolic diameter in short axis M-mode and long axis B- and M-mode showed good repeatability and reliability. E-point septal separation was neither repeatable nor reliable. Conclusions and clinical importance The LVEDD measurements were repeatable and reliable when obtained and measured by 2 non-cardiologists in hemodynamically stable dogs with normal sinus rhythms. Further study of LVEDD measurements is recommended in FCU. The EPSS cannot be recommended based on these data.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Heart VentriclesEchocardiographyAnimalsDogsReproducibility of ResultsFemaleMaleObserver Variation

Stichwörter der Autor:innen

echocardiographyfocused cardiac ultrasoundleft ventricle

Autor:innen und Institutionen

  • Département clinique des animaux de compagnie, Université de Liège, Liège, Belgium.
  • Veterinary Teaching Hospital, Clinical Veterinary Medicine, University of illinois at Urbana-Champaign, Urbana, IL, United States.
  • Emergency and Critical Care, Centre Hospitalier Vétérinaire FREGIS, Paris, France.

Zitieren

APA

Kennedy, C. R., Jordan, A., Gommeren, K., & Merveille, A. C. (2026). Repeatability and reliability of left ventricular focused cardiac ultrasound parameters in dogs obtained and measured by two non-cardiologist clinicians. Journal of Veterinary Internal Medicine. https://doi.org/10.1093/jvimsj/aalaf090

Vancouver

Kennedy CR, Jordan A, Gommeren K, Merveille AC. Repeatability and reliability of left ventricular focused cardiac ultrasound parameters in dogs obtained and measured by two non-cardiologist clinicians. Journal of Veterinary Internal Medicine. 2026. doi:10.1093/jvimsj/aalaf090

BibTeX
@article{Kennedy2026,
  author = {Kennedy, Christopher R and Jordan, Aurelie and Gommeren, Kris and Merveille, Anne-Christine},
  title = {Repeatability and reliability of left ventricular focused cardiac ultrasound parameters in dogs obtained and measured by two non-cardiologist clinicians},
  journal = {Journal of Veterinary Internal Medicine},
  year = {2026},
  doi = {10.1093/jvimsj/aalaf090}
}
Kostenlos starten →