EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY 4.0

Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study

Dany E Weisz iD, Laura Thomas iD, Xiang Y Ye, Luc Mertens, Anie Lapointe, Andréanne Villeneuve, Gabriel Altit iD, Renjini Lalitha, Nadya Ben Fadel iD, George Jacob, Deepak Louis iD, Soume Bhattacharya und 14 weitere

Journal of Neonatal-Perinatal Medicine · 2025

DOI: 10.1177/19345798251349744 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Journal of Neonatal-Perinatal Medicine, 2025. Verfasst von Dany E Weisz und 25 weiteren Autor:innen. Beteiligte Einrichtung: Newborn and Developmental Paediatrics, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Ductus Arteriosus, Patent, Infant, Extremely Premature, Echocardiography. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Canadian Institutes for Health Research.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Prior studies on the reliability of targeted neonatal echocardiography (TNE) among extremely low gestational age neonates (ELGANs) with a patent ductus arteriosus (PDA) have been limited to evaluation of pre-defined images by a small set of study observers. The objective of this study was to investigate the interobserver reliability of comprehensive echocardiography measures of PDA size/shunt volume and ventricular performance among TNE-neonatologists in a large national network.

Methods

We conducted a prospective observational study. TNEs performed for the evaluation of PDA among ELGANs were analyzed by TNE-neonatologists from the Canadian TNE Consortium. Analyses were conducted via an interactive videoconferencing platform offering full remote control to the review software. Reliability for continuous measures was evaluated using the intraclass correlation coefficient (ICC) and coefficient of variation. The kappa statistic was used to evaluate the interobserver reliability of categorical parameters.

Results

Reliability was excellent among indices of PDA size and gradient (ICC≥0.91) and good-to-excellent among most indices of left ventricular (LV) size and output (ICC≥0.79, except for LV end-systolic volume and left atrium to aortic root ratio). There was substantial to near-complete agreement on PDA shunt direction and diastolic flow abnormalities in the abdominal aorta and systemic arteries (kappa ≥0.78). However, reliability for measures of LV systolic and diastolic performance was variable with ICC range 0.21–0.95, though with low coefficient of variation (

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ductus Arteriosus, PatentInfant, Extremely PrematureEchocardiographyHumansInfant, NewbornProspective StudiesReproducibility of ResultsFemaleObserver VariationMaleCanadaHeart VentriclesGestational Age

Stichwörter der Autor:innen

PDATNEcoefficient of variationintraclass correlation coefficientkappa statisticpatent ductus arteriosusprematuretargeted neonatal echocardiography

Autor:innen und Institutionen

  • Newborn and Developmental Paediatrics, Sunnybrook Health Sciences Centre, Toronto, Ontario, Canada.
  • Department of Paediatrics, University of Toronto, Toronto, Ontario, Canada.
  • Department of Paediatrics, Mount Sinai Hospital, Toronto, Ontario, Canada.
  • Maternal-Infant Care Research Centre, Mount Sinai Hospital, Toronto, Ontario, Canada.
  • Division of Paediatric Cardiology, Hospital for Sick Children, Toronto, Ontario, Canada.
  • Division of Neonatology, CHU Sainte Justine, Montréal, Quebec, Canada.

ORCID-Profile: Dany E Weisz, Laura Thomas, Gabriel Altit, Nadya Ben Fadel, Deepak Louis, Joseph Y Ting, Aimann Surak, Poorva Deshpande, Bonny Jasani, Sagee Nissimov, Faith Zhu, Prakesh Shah, Amish Jain

Förderung

  • Canadian Institutes for Health Research

Zitieren

APA

Weisz, D. E., Thomas, L., Ye, X. Y., Mertens, L., Lapointe, A., Villeneuve, A., Altit, G., Lalitha, R., Ben Fadel, N., Jacob, G., Louis, D., Bhattacharya, S., Soraisham, A., Hébert, A., Mitra, S., Hyderi, A., Ting, J. Y., Castaldo, M., Surak, A., …, & Jain, A. (2025). Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study. Journal of Neonatal-Perinatal Medicine. https://doi.org/10.1177/19345798251349744

Vancouver

Weisz DE, Thomas L, Ye XY, Mertens L, Lapointe A, Villeneuve A, et al. Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study. Journal of Neonatal-Perinatal Medicine. 2025. doi:10.1177/19345798251349744

BibTeX
@article{Weisz2025,
  author = {Weisz, Dany E and Thomas, Laura and Ye, Xiang Y and Mertens, Luc and Lapointe, Anie and Villeneuve, Andréanne and Altit, Gabriel and Lalitha, Renjini and Ben Fadel, Nadya and Jacob, George and Louis, Deepak and Bhattacharya, Soume and Soraisham, Amuchou and Hébert, Audrey and Mitra, Souvik and Hyderi, Abbas and Ting, Joseph Y and Castaldo, Michael and Surak, Aimann and Deshpande, Poorva and Elsayed, Yasser and Jasani, Bonny and Nissimov, Sagee and Zhu, Faith and Shah, Prakesh and Jain, Amish},
  title = {Reliability of comprehensive echocardiography evaluation of patent ductus arteriosus among extremely preterm neonates across a national network: A prospective observational study},
  journal = {Journal of Neonatal-Perinatal Medicine},
  year = {2025},
  doi = {10.1177/19345798251349744}
}
Kostenlos starten →