EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Accuracy of 6-lead electrocardiography in identifying subclinical hypertrophic cardiomyopathy in cats

Larissa Gardner iD, Catheryn Partington iD, Jose Novo Matos iD

Journal of Veterinary Internal Medicine · 2026

DOI: 10.1093/jvimsj/aalaf009 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Veterinary Internal Medicine, 2026. Verfasst von Larissa Gardner und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Medicine, University of Cambridge, Madingley Road, Cambridge CB3 0ES, United Kingdom. Hauptthemen laut MEDLINE: Cardiomyopathy, Hypertrophic, Electrocardiography, Cat Diseases. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 59 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In people, electrocardiography (ECG) is recommended for screening of hypertrophic cardiomyopathy (HCM). Data for assessing the ability of ECG to screen HCM in apparently healthy cats is scarce. Hypothesis/Objectives Determine whether ECG variables on a 6-lead ECG can identify subclinical HCM in cats. Animals One hundred twelve cats were enrolled, 61 normal and 51 with subclinical HCM.

Methods

Single-center, cross-sectional study. Cats with normal hearts (end-diastolic left ventricular wall thickness [LVWTd] ≤ 5.0 mm) and cats with subclinical HCM (LVWTd ≥ 6.0 mm) were prospectively enrolled. Blinded assessment of the following ECG variables was performed: P wave amplitude and duration, PQ interval duration, amplitude of Q, R, and S waves, QRS duration, dispersion and mean electrical axis, R-to-peak time, T wave amplitude and duration, T/R ratio, T peak-to-end time (Tpte), Tpte/QT, RT concordance, QT interval (absolute and corrected for heart rate), presence of ST segment elevation (STE)/depression, and J wave.

Results

On multivariable analysis, a higher R wave amplitude (odds ratio [OR], 20.12; 95% confidence interval [CI], 2.4-227.5) and presence of STE ($\ge$0.04 mV; OR, 8.3; 95% CI, 2.9-27.4) were the only variables independently associated with HCM after adjusting for body weight (area under the curve, 0.86; 95% CI, 0.78-0.93). An R wave amplitude > 0.26 mV as a sole screening test for HCM had 65% sensitivity and 62% specificity to detect HCM. Conclusions and clinical importance Our results suggest that a 6-lead ECG is a poor screening tool to detect subclinical HCM in cats.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cardiomyopathy, HypertrophicElectrocardiographyCat DiseasesAnimalsCatsFemaleMaleCross-Sectional StudiesSensitivity and Specificity

Stichwörter der Autor:innen

asymptomaticelectrocardiogramfelineleft ventricular hypertrophy; preclinical

Autor:innen und Institutionen

  • Department of Veterinary Medicine, University of Cambridge, Madingley Road, Cambridge CB3 0ES, United Kingdom.

ORCID-Profile: Larissa Gardner, Catheryn Partington, Jose Novo Matos

Zitieren

APA

Gardner, L., Partington, C., & Novo Matos, J. (2026). Accuracy of 6-lead electrocardiography in identifying subclinical hypertrophic cardiomyopathy in cats. Journal of Veterinary Internal Medicine. https://doi.org/10.1093/jvimsj/aalaf009

Vancouver

Gardner L, Partington C, Novo Matos J. Accuracy of 6-lead electrocardiography in identifying subclinical hypertrophic cardiomyopathy in cats. Journal of Veterinary Internal Medicine. 2026. doi:10.1093/jvimsj/aalaf009

BibTeX
@article{Gardner2026,
  author = {Gardner, Larissa and Partington, Catheryn and Novo Matos, Jose},
  title = {Accuracy of 6-lead electrocardiography in identifying subclinical hypertrophic cardiomyopathy in cats},
  journal = {Journal of Veterinary Internal Medicine},
  year = {2026},
  doi = {10.1093/jvimsj/aalaf009}
}
Kostenlos starten →