Effect of echocardiographic imaging view and methods on left ventricular wall-thickness measurements in normal cats and cats with hypertrophic cardiomyopathy
Journal of Veterinary Internal Medicine · 2026
DOI: 10.1093/jvimsj/aalag062 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Veterinary Internal Medicine, 2026. Verfasst von Giovanni Grosso und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Veterinary Sciences, University of Pisa, Pisa, Italy. Hauptthemen laut MEDLINE: Cardiomyopathy, Hypertrophic, Echocardiography, Cat Diseases, Heart Ventricles. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Echocardiographic measurements of left ventricular free wall (LVFW) and interventricular septum (IVS) thickness are essential for diagnosing hypertrophic cardiomyopathy (HCM). Hypothesis/Objectives To evaluate agreement between different imaging views and modes for assessing LV wall thickness in cats. We hypothesized that there is clinically relevant bias between methods, and that results cannot be used interchangeably. Animals Two-hundred eighty cats; 140 controls and 140 with subclinical HCM.
Methods
Retrospective, single-center, and cross-sectional study. End-diastolic IVS and LVFW thickness was evaluated by 2-dimensional (2D) and time-motion mode (M-mode) echocardiography, from right parasternal long-axis (RPLax) and right parasternal short-axis (RPSax) views: method-1 (M1), RPLax using 2D; M2, RPLax using M-mode; M3, RPSax using 2D; and M4, RPSax using M-mode. Using 2D images, the thickest portion of the LV wall was measured. Methods were compared using repeated measurement ANOVA on ranks and the Bland–Altman method with bias and 95% limits of agreement (95% LOA).
Results
In controls, IVS thickness was not different among the 4 methods (P = .67; bias 0.04-0.10 mm, 95% LOA −1.09 to 1.28 mm); whereas LVFW thickness was (P < .001) using M-mode compared to 2D (bias 0.22-0.30 mm; 95% LOA −0.81 to 1.25 mm). In HCM cats, thickness of the IVS (bias −1.07 to −1.13 mm; 95% LOA −3.05 to 0.84 mm) and LVFW (bias 0.22 to −.27 mm; 95% LOA −2.09 to 2.03 mm) was different among methods (P < .001). Conclusions and clinical importance Two-dimensional and M-mode echocardiographic methods in the assessment of LV wall thickness cannot be used interchangeably, particularly in cats with HCM.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Veterinary Sciences, University of Pisa, Pisa, Italy.
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, The Ohio State University, Columbus, OH, United States.
Zitieren
APA
Grosso, G., & Schober, K. E. (2026). Effect of echocardiographic imaging view and methods on left ventricular wall-thickness measurements in normal cats and cats with hypertrophic cardiomyopathy. Journal of Veterinary Internal Medicine. https://doi.org/10.1093/jvimsj/aalag062
Vancouver
Grosso G, Schober KE. Effect of echocardiographic imaging view and methods on left ventricular wall-thickness measurements in normal cats and cats with hypertrophic cardiomyopathy. Journal of Veterinary Internal Medicine. 2026. doi:10.1093/jvimsj/aalag062
BibTeX
@article{Grosso2026,
author = {Grosso, Giovanni and Schober, Karsten Eckhard},
title = {Effect of echocardiographic imaging view and methods on left ventricular wall-thickness measurements in normal cats and cats with hypertrophic cardiomyopathy},
journal = {Journal of Veterinary Internal Medicine},
year = {2026},
doi = {10.1093/jvimsj/aalag062}
}
EUVIMED