Repair of penile prosthesis–induced impending erosion using xenograft during simultaneous inflatable penile prosthesis replacement

Joshua S Jue, Jean-Francois Eid

The Journal of Sexual Medicine · 2023

DOI: 10.1093/jsxmed/qdad127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift The Journal of Sexual Medicine, 2023. Verfasst von Joshua S Jue und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Lenox Hill Hospital, Northwell Health, Zucker School of Medicine at Hofstra/Northwell, New York, NY 10075, United States. Hauptthemen laut MEDLINE: Penile Prosthesis, Erectile Dysfunction, Penile Diseases, Penile Implantation. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Penile prosthesis (PP)–induced impending erosion is a rare complication that has not been well characterized.

Aim

This study evaluates the role of prosthesis sizing and of the safety of xenograft windsock repair (AlloDerm, Tutoplast, ArthroFLEX) of impending erosion.

Methods

This was a retrospective review of xenograft use during inflatable penile prosthesis (IPP) replacement. Patient demographics, prior PP characteristics, and xenograft-augmented IPP characteristics were obtained. Paired-samples t tests were used to compare the PP cylinder size, rear tip extender size, and calculated PP length between the most recent prior PP and the xenograft-augmented IPP. Complications and follow-up data were obtained. Outcomes The primary outcome was comparing the corporal body and device measurements between the PP presenting with impending erosion and the implanted xenograft-augmented IPP. The secondary outcome was evaluating the incidence of subsequent explantation.

Results

A total of 24 patients underwent xenograft repair with simultaneous IPP replacement from 2012 to 2022. The median number of prior PP was 1 (interquartile range, 1-2.75). The median time between the most recent prior PP and xenograft-augmented IPP placement was 21 (interquartile range, 14-79) months. The prior PP was significantly longer at the time of explantation compared with the measured corporal body length in both the left (21.4 cm vs 20.1 cm; P < .01) and right (21.4 cm vs 20.1 cm; P < .01) sides. However, there was no significant difference in length between the xenograft-augmented IPP length at the time of implantation and measured corporal body length in both the left (20.1 cm vs 20.0 cm; P = .67) and right (20.2 cm vs 20.1 cm; P = .56) sides. A total of 16 (66.7%) cases required bilateral xenograft corporal body use. Only 1 (4.2%) patient had an IPP infection requiring explantation within 90 days of xenograft-augmented IPP placement. A total of 2 (8.3%) patients had device malfunction and 1 (4.2%) patient had impending erosion recurrence requiring removal/replacement of their initial xenograft-augmented IPP in a median time of 56 months from placement. Clinical Implications PP oversizing may increase risk of PP-induced impending erosion, which is a delayed process. Strengths and Limitations This is the largest retrospective study of xenograft use during IPP replacement for impending erosion but does not have a control cohort. This study is limited by its retrospective nature, limited follow-up, and absence of a treatment comparison.

Conclusion

PP-induced impending erosion may be due to PP oversizing but can be successfully repaired with xenograft windsock during simultaneous IPP replacement.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Penile ProsthesisErectile DysfunctionPenile DiseasesPenile ImplantationHumansMaleRetrospective StudiesHeterograftsPatient Satisfaction

Stichwörter der Autor:innen

IPPerectile dysfunctionpenile prosthesistissue graftxenograft

Autor:innen und Institutionen

  • Department of Urology, Lenox Hill Hospital, Northwell Health, Zucker School of Medicine at Hofstra/Northwell, New York, NY 10075, United States.

Zitieren

APA

Jue, J. S., & Eid, J. F. (2023). Repair of penile prosthesis–induced impending erosion using xenograft during simultaneous inflatable penile prosthesis replacement. The Journal of Sexual Medicine. https://doi.org/10.1093/jsxmed/qdad127

Vancouver

Jue JS, Eid JF. Repair of penile prosthesis–induced impending erosion using xenograft during simultaneous inflatable penile prosthesis replacement. The Journal of Sexual Medicine. 2023. doi:10.1093/jsxmed/qdad127

BibTeX
@article{Jue2023,
  author = {Jue, Joshua S and Eid, Jean-Francois},
  title = {Repair of penile prosthesis–induced impending erosion using xenograft during simultaneous inflatable penile prosthesis replacement},
  journal = {The Journal of Sexual Medicine},
  year = {2023},
  doi = {10.1093/jsxmed/qdad127}
}
Kostenlos starten →