Excellent long-term device survival of inflatable penile prosthesis over 27 years
Asian Journal of Andrology · 2026
DOI: 10.4103/aja2024112 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Asian Journal of Andrology, 2026. Verfasst von Ignacio Moncada und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology and Robotic Surgery, La Zarzuela University Hospital, Madrid 28023, Spain. Hauptthemen laut MEDLINE: Penile Prosthesis, Erectile Dysfunction, Prosthesis Failure, Penile Implantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
The study aimed to assess the long-term device survival of a 3-piece inflatable penile prosthesis (PP) in patients with erectile dysfunction (ED). This retrospective observational longitudinal study involved patients with drug-refractory ED who underwent primary 3-piece inflatable PP implantation at a single center from 1992 to 2019. The outcomes included complications of various inflatable PP models, and Kaplan–Meier analysis was used to estimate the probability of PP survival. Of the total 426 patients, 140 (32.9%) were implanted in the period of 1992–2000, 128 (30.0%) in the period of 2001–2008, and 158 (37.1%) in the period of 2009–2019. The PP used in the study included AMS 700 CX (62.0%, n = 264), AMS 700 CXR (7.7%, n = 33), AMS Ultrex Plus (10.3%, n = 44), and Alpha I (20.0%, n = 85). The overall complication rate was 28.2% (120/426), and the majority happened after 6 months. The causes of device removal included mechanical failure (11.0%, n = 47), infection (3.9%, n = 17), cylinder extrusion (6.3%, n = 27), and unspecified (0.2%, n = 1). Of the total mechanical failures ( n = 47), 18 (38.3%) occurred in the cylinders, 10 (21.3%) occurred in the pump, 7 (14.9%) occurred in the reservoir, 6 (12.8%) occurred in the connections, and 6 (12.8%) were nonspecific. Global average survival rates of the PP at 1 year, 5 years, 10 years, and 15 years were 96.2%, 86.7%, 77.5%, and 58.7%, respectively. The 3-piece inflatable PP has an excellent device survival rate at 5 years and 10 years.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Urology and Robotic Surgery, La Zarzuela University Hospital, Madrid 28023, Spain.
- Andrology Division, Department of Urology and Robotic Surgery, AndroNeo, Orchidz Health, NU Hospitals, Bengaluru 560010, Karnataka, India.
- Lyx Institute of Urology, Francisco de Vitoria University, Madrid 28006, Spain.
- Department of Urology, Puerta De Hierro-Majadahonda University Hospital, Madrid 28222, Spain.
- Department of Urology, Gregorio Maranon University General Hospital, Complutense University, Madrid 28007, Spain.
Zitieren
APA
Moncada, I., Krishnappa, P., Martinez-Salamanca, J. I., Palma-Hendges, L. P., Gonzalez-Garcia, F. J., Hernandez-Fernandez, C., & Lledo-Garcia, E. (2026). Excellent long-term device survival of inflatable penile prosthesis over 27 years. Asian Journal of Andrology. https://doi.org/10.4103/aja2024112
Vancouver
Moncada I, Krishnappa P, Martinez-Salamanca JI, Palma-Hendges LP, Gonzalez-Garcia FJ, Hernandez-Fernandez C, et al. Excellent long-term device survival of inflatable penile prosthesis over 27 years. Asian Journal of Andrology. 2026. doi:10.4103/aja2024112
BibTeX
@article{Moncada2026,
author = {Moncada, Ignacio and Krishnappa, Pramod and Martinez-Salamanca, Juan Ignacio and Palma-Hendges, Luiz Pedro and Gonzalez-Garcia, Francisco Javier and Hernandez-Fernandez, Carlos and Lledo-Garcia, Enrique},
title = {Excellent long-term device survival of inflatable penile prosthesis over 27 years},
journal = {Asian Journal of Andrology},
year = {2026},
doi = {10.4103/aja2024112}
}
EUVIMED