Evaluation of radiation protection by lead glasses for interventional radiology physicians wearing prescription glasses: considering dose reduction by prescription glasses excluding lead
Journal of Radiation Research · 23.09.2025 · 66 (5) · 486-495
DOI: 10.1093/jrr/rraf047 ↗Kurz gefasst
Evaluationsstudie in der Zeitschrift Journal of Radiation Research, online erschienen am 11.08.2025. Verfasst von Ryota Shindo und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan. Hauptthemen laut MEDLINE: Radiation Protection, Lead, Eyeglasses, Radiation Dosage. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 69 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Japan Science and Technology Agency, Industrial Disease Clinical Research, Japan Society for the Promotion of Science.
Abstract (Originalsprache)
The International Commission on Radiological Protection has reduced the occupational eye lens dose limit to 20 mSv/year. Interventional radiology (IR) physicians are frequently exposed to high levels of scattered X-rays, and radiation protection tools, including lead glasses, are used for minimizing exposure. However, the effectiveness of lead eyewear for radiation workers who wear prescription glasses (e.g. over-glasses-type eyewear) has not been comprehensively investigated. This study evaluated the shielding effectiveness of over-glasses-type eyewear worn over plastic prescription glasses through phantom experiments. Furthermore, the dose reduction provided by the plastic lenses and front frame of the prescription glasses (excluding lead) was assessed. The over-glasses-type eyewear demonstrated high shielding effectiveness, with average shielding rates of 0.72–0.74 and 0.74–0.80 for the left and right eyes, respectively, against radiation incident from the lower left oblique, as typically encountered in clinical settings. In contrast, the plastic lenses of prescription glasses provided <9% dose reduction when it irradiated with 80- and 120-kV X-rays, indicating minimal contribution to eye protection. The plastic front frame offered a 14% reduction at 80 kV and 11% at 120 kV. These findings suggest that the front frame of the prescription glasses contributes to photon attenuation and improves overall shielding. However, the improper fit of over-glasses-type eyewear may lead to gaps, compromising its shielding effectiveness. To minimize gaps and optimize protection, IR physicians should select over-glasses-type eyewear that fits securely over prescription glasses. Additionally, combining protective tools is essential for effective eye protection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan.
- Division of Radiological Disasters and Medical Science, Department of Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, 6-6-4, Aoba, Sendai 980-8579, Japan.
ORCID-Profile: Ryota Shindo, Yohei Inaba, Masatoshi Suzuki, Koichi Chida
Förderung
- Japan Science and Technology Agency
- Industrial Disease Clinical Research
- Japan Society for the Promotion of Science
Zitieren
APA
Shindo, R., Yamamoto, K., Ohno, S., Konta, S., Inaba, Y., Suzuki, M., Zuguchi, M., & Chida, K. (2025). Evaluation of radiation protection by lead glasses for interventional radiology physicians wearing prescription glasses: considering dose reduction by prescription glasses excluding lead. Journal of Radiation Research, 66(5), 486-495. https://doi.org/10.1093/jrr/rraf047
Vancouver
Shindo R, Yamamoto K, Ohno S, Konta S, Inaba Y, Suzuki M, et al. Evaluation of radiation protection by lead glasses for interventional radiology physicians wearing prescription glasses: considering dose reduction by prescription glasses excluding lead. Journal of Radiation Research. 2025;66(5):486-495. doi:10.1093/jrr/rraf047
BibTeX
@article{Shindo2025,
author = {Shindo, Ryota and Yamamoto, Keisuke and Ohno, Saya and Konta, Satoe and Inaba, Yohei and Suzuki, Masatoshi and Zuguchi, Masayuki and Chida, Koichi},
title = {Evaluation of radiation protection by lead glasses for interventional radiology physicians wearing prescription glasses: considering dose reduction by prescription glasses excluding lead},
journal = {Journal of Radiation Research},
year = {2025},
volume = {66},
number = {5},
pages = {486--495},
doi = {10.1093/jrr/rraf047}
}
EUVIMED