EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Clinical workload profile of medical physics professionals at particle therapy Centers: a National Survey in Japan

Seiichi Ota, Keisuke Yasui, Toshiyuki Ogata, Yutaro Mori, Teiji Nishio, Naoki Tohyama, Hiroyuki Okamoto, Masahiko Kurooka, Kohei Shimomura, Toru Kojima, Hiroshi Onishi

Journal of Radiation Research · 2025

DOI: 10.1093/jrr/rrae092 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Radiation Research, 2025. Verfasst von Seiichi Ota und 10 weiteren Autor:innen. Beteiligte Einrichtung: Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, 465 Kajii-cho, …. Hauptthemen laut MEDLINE: Workload, Health Physics. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Ministry of Health, Labor, and Welfare for Health Sciences Research in Japan.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The current research on staffing models is primarily focused on conventional external photon beam therapy, which predominantly involves using linear accelerators. This emphasizes the need for comprehensive studies to understand better and define specific particle therapy facilities’ staffing requirements. In a 2022 survey of 25 particle therapy facilities in Japan with an 84% response rate, significant insights were obtained regarding workload distribution, defined as the product of personnel count and task time (person-minutes), for patient-related tasks and equipment quality assurance and quality control (QA/QC). The survey revealed that machinery QA/QC tasks were particularly demanding, with an average monthly workload of 376.9 min and weekly tasks averaging 162.1 min. In comparison, patient-related workloads focused on treatment planning, exhibiting substantial time commitments, particularly for scanning and passive scattering techniques. The average workloads for treatment planning per patient were 291.3 and 195.4 min, respectively. In addition, specific patient scenarios such as pre-treatment sedation in pediatric cases require longer durations (averaging 84.5 min), which likely include the workloads of not only the physician responsible for sedation but also the radiotherapy technology and medical physics specialists providing support during sedation and the nursing staff involved in sedation care. These findings underscore the significant time investments required for machinery QA/QC and patient-specific treatment planning in particle therapy facilities, along with the need for specialized care procedures in pediatric cases. The results of this survey also emphasized the challenges and staffing requirements to ensure QA/QC in high-precision medical environments.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WorkloadHealth PhysicsJapanHumansSurveys and QuestionnairesQuality Control

Stichwörter der Autor:innen

FTERTTcarbon ion therapymedical physicistproton therapyworkload

Autor:innen und Institutionen

  • Division of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
  • Division of Medical Physics, School of Medical Sciences, Fujita Health University, 1-98 Dengakugakubo, Kutsukakecho, Toyoake, Aichi 470-1192, Japan.
  • Department of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
  • Department of Radiation Oncology, Institute of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan.
  • Medical Physics Laboratory, Division of Health Science, Graduate School of Medicine, Osaka University, 1-7 Yamadaoka, Suita, Osaka 565-0871, Japan.
  • Department of Radiological Sciences, Komazawa University, 1-23-1 Komazawa, Setagaya-ku, Tokyo 154-8525, Japan.

Förderung

  • Ministry of Health, Labor, and Welfare for Health Sciences Research in Japan

Zitieren

APA

Ota, S., Yasui, K., Ogata, T., Mori, Y., Nishio, T., Tohyama, N., Okamoto, H., Kurooka, M., Shimomura, K., Kojima, T., & Onishi, H. (2025). Clinical workload profile of medical physics professionals at particle therapy Centers: a National Survey in Japan. Journal of Radiation Research. https://doi.org/10.1093/jrr/rrae092

Vancouver

Ota S, Yasui K, Ogata T, Mori Y, Nishio T, Tohyama N, et al. Clinical workload profile of medical physics professionals at particle therapy Centers: a National Survey in Japan. Journal of Radiation Research. 2025. doi:10.1093/jrr/rrae092

BibTeX
@article{Ota2025,
  author = {Ota, Seiichi and Yasui, Keisuke and Ogata, Toshiyuki and Mori, Yutaro and Nishio, Teiji and Tohyama, Naoki and Okamoto, Hiroyuki and Kurooka, Masahiko and Shimomura, Kohei and Kojima, Toru and Onishi, Hiroshi},
  title = {Clinical workload profile of medical physics professionals at particle therapy Centers: a National Survey in Japan},
  journal = {Journal of Radiation Research},
  year = {2025},
  doi = {10.1093/jrr/rrae092}
}
Kostenlos starten →