Effect of backscatter radiation on the occupational eye-lens dose
Journal of Radiation Research · 2024
DOI: 10.1093/jrr/rrae034 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiation Research, 2024. Verfasst von Saya Ohno und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan. Hauptthemen laut MEDLINE: Scattering, Radiation, Lens, Crystalline, Occupational Exposure, Phantoms, Imaging. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 64 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Japan Society for the Promotion of Science, Industrial Disease Clinical Research Grants.
Abstract (Originalsprache)
We quantified the level of backscatter radiation generated from physicians’ heads using a phantom. We also evaluated the shielding rate of the protective eyewear and optimal placement of the eye-dedicated dosimeter (skin surface or behind the Pb-eyewear). We performed diagnostic X-rays of two head phantoms: Styrofoam (negligible backscatter radiation) and anthropomorphic (included backscatter radiation). Radiophotoluminescence glass dosimeters were used to measure the eye-lens dose, with or without 0.07-mm Pb-equivalent protective eyewear. We used tube voltages of 50, 65 and 80 kV because the scattered radiation has a lower mean energy than the primary X-ray beam. The backscatter radiation accounted for 17.3–22.3% of the eye-lens dose, with the percentage increasing with increasing tube voltage. Furthermore, the shielding rate of the protective eyewear was overestimated, and the eye-lens dose was underestimated when the eye-dedicated dosimeter was placed behind the protective eyewear. We quantified the backscatter radiation generated from physicians’ heads. To account for the effect of backscatter radiation, an anthropomorphic, rather than Styrofoam, phantom should be used. Close contact of the dosimeter with the skin surface is essential for accurate evaluation of backscatter radiation from physician’s own heads. To assess the eye-lens dose accurately, the dosimeter should be placed near the eye. If the dosimeter is placed behind the lens of the protective eyewear, we recommend using a backscatter radiation calibration factor of 1.2–1.3.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiological Technology, Tohoku University Graduate School of Medicine, 2-1 Seiryo, Aoba, Sendai 980-8575, Japan.
- Division of Radiological Disasters and Medical Science, Department of Disaster Medicine, International Research Institute of Disaster Science, Tohoku University, 6-6-4, Aoba, Sendai 980-8579, Japan.
Förderung
- Japan Society for the Promotion of Science
- Industrial Disease Clinical Research Grants
Zitieren
APA
Ohno, S., Konta, S., Shindo, R., Yamamoto, K., Isobe, R., Inaba, Y., Suzuki, M., Zuguchi, M., & Chida, K. (2024). Effect of backscatter radiation on the occupational eye-lens dose. Journal of Radiation Research. https://doi.org/10.1093/jrr/rrae034
Vancouver
Ohno S, Konta S, Shindo R, Yamamoto K, Isobe R, Inaba Y, et al. Effect of backscatter radiation on the occupational eye-lens dose. Journal of Radiation Research. 2024. doi:10.1093/jrr/rrae034
BibTeX
@article{Ohno2024,
author = {Ohno, Saya and Konta, Satoe and Shindo, Ryota and Yamamoto, Keisuke and Isobe, Rio and Inaba, Yohei and Suzuki, Masatoshi and Zuguchi, Masayuki and Chida, Koichi},
title = {Effect of backscatter radiation on the occupational eye-lens dose},
journal = {Journal of Radiation Research},
year = {2024},
doi = {10.1093/jrr/rrae034}
}
EUVIMED