Comparative dosimetric and radiobiological assessment of left-sided whole breast and regional nodes with advanced radiotherapy techniques
Journal of Radiation Research · 18.07.2023 · 64 (4) · 677-684
DOI: 10.1093/jrr/rrad045 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Radiation Research, online erschienen am 14.06.2023. Verfasst von Yuling Huang und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang, Jiangxi 330029, PR China. Hauptthemen laut MEDLINE: Radiotherapy, Intensity-Modulated, Breast Neoplasms. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 43 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Science and Technology Project of Jiangxi Provincial Health Commission of China.
Abstract (Originalsprache)
The aim of this study was to analyze the dosimetric and radiobiologic differences of the left-sided whole breast and regional nodes in intensity-modulated radiotherapy (IMRT), volume-modulated arc therapy (VMAT), and helical tomotherapy (HT). The IMRT, VMAT, and HT plans in this study were generated for thirty-five left-sided breast cancer patients after breast-conserving surgery (BCS). The planning target volume (PTV) included the whole breast and supraclavicular nodes. PTV coverage, homogeneity index (HI), conformity index (CI), dose to organs at risk (OARs), secondary cancer complication probability (SCCP), and excess absolute risk (EAR) were used to evaluate the plans. Compared to IMRT, the VMAT and HT plans resulted in higher PTV coverage and homogeneity. The VMAT and HT plans also delivered a lower mean dose to the ipsilateral lung (9.19 ± 1.36 Gy, 9.48 ± 1.17 Gy vs. 11.31 ± 1.42 Gy) and heart (3.99 ± 0.86 Gy, 4.48 ± 0.62 Gy vs. 5.53 ± 1.02 Gy) and reduced the V5Gy, V10Gy, V20Gy, V30Gy, and V40Gy of the ipsilateral lung and heart. The SCCP and EAR for the ipsilateral lung were reduced by 3.67%, 3.09% in VMAT, and 22.18%, 19.21% in HT, respectively. While were increased for the contralateral lung and breast. This study showed that VMAT plans provide a more homogeneous dose distribution to the PTV, minimizing exposure to ipsilateral structures and significantly reducing SCCP and EAR, and slightly increasing dose to contralateral structures. Overall, the VMAT plan can be considered a beneficial technique for BCS patients whose PTV includes the whole breast and regional nodes.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Oncology, Jiangxi Cancer Hospital, 519 East Beijing Road, Qingshanhu District, Nanchang, Jiangxi 330029, PR China.
- Department of Radiation Oncology, The Second Affiliated Hospital of Nanchang, Nanchang, Jiangxi 330029, PR China.
Förderung
- Science and Technology Project of Jiangxi Provincial Health Commission of China
Zitieren
APA
Huang, Y., Gong, C., Luo, M., Yuan, X., Ding, S., Wang, X., & Zhang, Y. (2023). Comparative dosimetric and radiobiological assessment of left-sided whole breast and regional nodes with advanced radiotherapy techniques. Journal of Radiation Research, 64(4), 677-684. https://doi.org/10.1093/jrr/rrad045
Vancouver
Huang Y, Gong C, Luo M, Yuan X, Ding S, Wang X, et al. Comparative dosimetric and radiobiological assessment of left-sided whole breast and regional nodes with advanced radiotherapy techniques. Journal of Radiation Research. 2023;64(4):677-684. doi:10.1093/jrr/rrad045
BibTeX
@article{Huang2023,
author = {Huang, Yuling and Gong, Changfei and Luo, Mingming and Yuan, Xingxing and Ding, Shenggou and Wang, Xiaoping and Zhang, Yun},
title = {Comparative dosimetric and radiobiological assessment of left-sided whole breast and regional nodes with advanced radiotherapy techniques},
journal = {Journal of Radiation Research},
year = {2023},
volume = {64},
number = {4},
pages = {677--684},
doi = {10.1093/jrr/rrad045}
}